Kegerator
Páginas: 9 (2116 palabras)
Publicado: 12 de marzo de 2013
ASSEMBLY & USE MANUAL
SAFETY FIRST!
Read safety guidelines before assembling and plugging into electrical outlet.
• •
CO2 can be dangerous.
Flush chemical out of beer line completely before re-tapping keg.
Micro Matic has a policy of continuous improvement and reserves the right to change materials and specifications without notice.
www.MicroMatic.comToll Free: 1 (866) 291-5756
60-006 16 05-05
PLEASE READ BEFORE USE
WARNINGS
KEG OPERATION
1. NEVER exceed 60 P.S.I. 2. ALWAYS use a keg coupler and gas pressure regulator equipped with a pressure relief device. 3. NEVER try to remove the valve in the keg.
CO2 GAS
1. 2. 3. 4. 5. 6. ALWAYS connect CO2 gas cylinder to regulator. NEVER connect gas cylinder directly to keg. ALWAYS securegas cylinder in an upright position. ALWAYS keep gas cylinder away from heat. Store in a cool location under 70º F. NEVER drop or throw gas cylinder. ALWAYS ventilate area after CO2 leakage. If it becomes difficult to breathe and your head starts to ache, high levels of CO2 (carbon dioxide) may be present in the area. LEAVE THE ROOM IMMEDIATELY.
CLEANING CHEMICAL
Beer line cleaner is a clear,odorless liquid containing potassium hydroxide.
Copyright © 2005 by Micro Matic USA, Inc. All Rights Reserved
1. ALWAYS use cleaning chemical with the manual cleaning bottle following the enclosed procedures. 2. ALWAYS wear safety glasses to protect eyes and rubber gloves for skin protection. 3. ALWAYS wash hands with soap and water after using chemical. 4. ALWAYS flush chemical completely withwater before re-tapping keg. 5. KEEP OUT of reach of children. 6. ALWAYS dispose of used chemical in accordance with federal and local regulations. 7. CALL physician or poison control center if product is swallowed. If ingested, drink large quantities of water to dilute chemical.
www.MicroMatic.com Toll Free: 1 (866) 291-5756
2
BASIC CONVERSION KIT COMPONENTS 4301 Shank, Faucet & 4933KKnob Assembly 4334NA-3
OPTIONAL EQUIPMENT
AVAILABLE DRIP TRAYS
Door Spacer RK-DS4 Faucet Wrench 4350-E Beer Hose with Fittings 5” x 3/16” I.D. 547C60A Hex Nut Washer 759 Beer Line Snap Clamp SNP-6 American Coupler Sankey D System 7485E
CO2 Regulator Dual Gauge 842
Removable Tray RK-DTA
Keyhole Mount DP-6X4 5 lb. Cylinder CO2 430A-5E (empty)
CO2 Regulator Single Gauge 841
CO2Hose 4’ x 5/16” I.D 553R Gas Hose Snap Clamps SNP-10
Cleaning Kit CK-1100
Shank Mount DP-321D-1
www.MicroMatic.com Toll Free: 1 (866) 291-5756
3
Copyright © 2005 by Micro Matic USA, Inc. All Rights Reserved
KEGERATOR DOOR KIT
Shank Hole Drilling Required Tools
Screwdriver (Flat head)
Drill & Bit
Hole Saw
Saw
Pencil
Tape Measure
Crescent Wrench
A
BCopyright © 2005 by Micro Matic USA, Inc. All Rights Reserved
NOTE: Please see drip tray mounting instructions for measurements before completing to Step B.
www.MicroMatic.com Toll Free: 1 (866) 291-5756
4
ASSEMBLY & USE MANUAL
Drip Tray Mounting Instructions
Shank Hole
43/4”
12”
Keyhole Mount Tray DP-6X4
Removable Tray
11/4”
12”
Copyright © 2005 by Micro Matic USA,Inc. All Rights Reserved
Shank Mount Tray DP-321D-1
www.MicroMatic.com Toll Free: 1 (866) 291-5756
5
KEGERATOR DOOR KIT
Faucet & Shank Mounting
C
D
Copyright © 2005 by Micro Matic USA, Inc. All Rights Reserved
E
www.MicroMatic.com Toll Free: 1 (866) 291-5756
6
ASSEMBLY & USE MANUAL
C02 Regulator Mounting & Pressure Hose Connection
F
Place the CO2 cylinder andregulator inside one of the corners of the refrigerator. It is important the cylinder be kept in an upright position to operate efficiently. Use a chain to secure.
G
“OFF” POSITION Snap Gas Clamp Line Regulator Hose Barb Snap Clamp Gas Line REGULATOR KEG COUPLER
Copyright © 2005 by Micro Matic USA, Inc. All Rights Reserved
www.MicroMatic.com Toll Free: 1 (866) 291-5756
7
KEGERATOR DOOR...
Leer documento completo
Regístrate para leer el documento completo.