Nominated 5th Data Centre 2012 European Awards
Cooling - Over Aisle Cooling

Ideal for medium and high density applications, the new APC InRow OA captures up to 27kW of hot IT exhaust air at the source, neutralises it and discharges cool, ambient air to the IT space. The OA includes integrated thermal containment, which eliminates mixing of hot and cold air streams – improving coolingpredictability. Modular construction, variable speed fans, and active response controls are all integrated into one high efficiency system. The over head design requires zero whitespace, because it can be mounted on a rack or suspended from the ceiling above the hot aisle, improving flexibility and the ability to adapt to existing data centre environments.
This refrigerant based system has beendeveloped to eliminate the threat from water leaks in close proximity to IT equipment. The refrigerant used in this modular, pumped system is R134a, a non-toxic solution that poses no threat to IT equipment in the event of a leak, and has no Ozone depletion potential.
The RDU is a refrigerant distribution unit capable of providing 160kW of heat rejection to the APC InRow OA cooling units, and its modularconstruction, variable speed pumps, and active response controls are integrated into the highly efficient variable volume pumping system. The RDU has the ability to modulate capacity from 0-100 percent with no minimum loading requirements and may be placed in the IT environment or in an adjacent location to further increase whitespace utilisation for IT equipment.
Other key components to thissystem include modular piping headers and the mounting structure of the APC InRow OA. The piping headers are an integrated part of the mounting structure of the APC InRow OA to simplify installation and reduce initial investment costs.
Key benefits of new APC InRow OA include:
· Ability to maximize available floor space for IT equipment
· Address concerns of water in the data centre
· 30-50%more efficient than traditional raised floor data centre cooling
· Elimination of hot spots caused by high density deployments
· Flexibility to easily deploy and redeploy cooling
· Simple to install minimising initial investment
Cooling Solutions – In-row Direct Expansion

The InRow Direct Expansion product design closely couples the cooling with the IT heat load. This design prevents hot airrecirculation, while improving cooling predictability and allowing for a pay as you grow environment. Available in self-contained, fluid cooled, and air-cooled configurations with or without humidity control, these products meet the diverse requirements for closets, server rooms, and data centers. IT operators looking to improve efficiency or deploy higher density equipment will benefit from themodular design of the InRow Direct Expansion products. The intelligent controls of the InRow Direct Expansion products actively adjust fan speed and refrigerant flow to match the IT heat load to maximize efficiency and address the dynamic demands of today’s IT environments.
Cooling Solutions – In-row Chilled Water

The InRow Chilled Water product design closely couples the cooling with the ITheat load. This design prevents hot air recirculation, while improving cooling predictability and allowing for a pay as you grow environment. Available with and without humidity control, these products are designed to meet the diverse requirements for medium to large data centers. Data center operators looking to improve efficiency or deploy high density servers will benefit from the modular designof the InRow Chilled Water products. The intelligent controls of the InRow Chilled Water products actively adjust fan speed and chilled water flow to match the IT heat load to maximize efficiency and address the dynamic demands of today’s IT environments.
Rack- Ethernet Switch

Rack - Speciality Enclosures

Specialty enclosures ensure reliable operation of your rack mount IT equipment in...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • Security
  • security
  • Security
  • Database security
  • Security Vocabulary
  • Penta Security
  • Security Manual
  • person security

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS