CONTROL DE

ANÁLISIS DE SOLUCIONES LÍQUIDAS
ÍTEM
1 2 3 4 5 6 7 8 9 10 11 12 13 14
DESCRIPCIÓN CÓDIGO

FECHA
12/04/10 12/04/10 13/04/10 13/04/10 14/04/10 14/04/10 14/04/10 15/04/10 15/04/10 16/04/10 16/04/10 17/04/10 17/04/10 17/04/10

MUESTREO
11:45 a.m. 11:45 a.m. 07:30 a.m. 08:00 a.m. 10:50 a.m. 10:50 a.m. 10:50 a.m. 07:30 a.m. 07:30 a.m. 07:30 a.m. 07:30 a.m. 07:30 a.m. 07:30 a.m.07:30 a.m.

[Cu+2] (gpl)
62,79 39,06 70,59 31,57 74,85 40,08 31,92 70,59 28,56 69,88 43,99 62,79 57,11 30,15

[H+] (gpl)
0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00

pH
2,81 3,12 2,68 2,48 2,78 2,91 2,70 2,94 3,61 2,83 3,28 2,60 2,92 2,22

ÁREA DE LAVADO Tanque 1 Tanque 2 Tanque 1 Tanque purga Tanque 1 Tanque 2 Tanque purga Tanque 1 Tanque 2 Tanque 1 Tanque 2Tanque 1 Tanque 2 Tanque purga T1P2 T2P2 T1P2 T3P2 T1P2 T2P2 T3P2 T1P2 T2P2 T1P2 T2P2 T1P2 T2P2 T3P2

ÁREA DE ELECTRODEPOSITACIÓN

Planta EW Planta EW Planta EW Planta EW Planta EW Planta EW Planta EW Planta EW Planta EW Planta EW

EWB10I EWB10 EWB10 EWB10 EWB10 EWB10 EWB10 EWB10 EWB10 EWB10

16/04/10 16/04/10 16/04/10 17/04/10 17/04/10 17/04/10 17/04/10 18/04/10 18/04/10 19/04/10

09:00a.m. 07:00 p.m. 11:00 p.m. 03:00 a.m. 07:00 a.m. 09:00 a.m. 11:00 a.m. 07:00 p.m. 11:00 p.m. 03:00 a.m.

0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00 0,00

0,00 1,47 4,17 7,60 9,8 11,76 12,98 21,07 23,28 24,50

2,85 1,31 1,07 0,84 0,76 0.73 0,72 0,43 0,37 0,32

Karina García Analista

CONTROL DE PARÁMETROS - PLANTA II
ANALISTA: Karina García Putapaña PERÍODO: 12/03 a 17/04 del2010

CEMENTACIÓN DE COBRE
INICIO DE PROCESO ÍTEM 1
2 3 4 5 6 7 8 9 10 11 12 13 14 15

FINAL DE PR ESTADO Operativo
Operativo Operativo Operativo Operativo Operativo Operativo Operativo Operativo Operativo Operativo Operativo Operativo Operativo Operativo

DESCRIPCIÓN Tromel 2
Tromel 3 Tromel 1 Tromel 2 Tromel 1 Tromel 2 Tromel 3 Tromel 1 Tromel 2 Tromel 3 Tromel 1 Tromel 2 Tromel 3 Tromel1 Tromel 2

TIPO Enjuague
Enjuague Enjuague Enjuague Enjuague Enjuague Enjuague Enjuague Enjuague Enjuague Enjuague Enjuague Enjuague Enjuague Enjuague

BATCH 246
247 248 249 250 251 252 253 254 255 256 257 258 259 260

FECHA 12/04/10
12/04/10 10/04/10 13/04/10 13/04/10 14/04/10 14/04/10 14/04/10 15/04/10 15/04/10 15/04/10 15/04/10 16/04/10 16/04/10 16/04/10

HORA 07:30 a.m.
03:10p.m. 11:50 p.m. 06:30 a.m. 07:30 p.m. 12:30 a.m. 09:00 a.m. 09:30 p.m. 12:45 a.m. 06:00 a.m. 08:00 p.m. 10:30 p.m. 06:30 a.m. 02:00 p.m. 11:55 p.m.

[Cu ] (gpl) 41,62
65,62 25,54 28,73 61,72 71,30 45,41 64,21 26,60 50,54 70,59 23,06 70,59 40,79 45,40

+2

pH 3,05
2,76 3,45 3,40 3,11 2,90 3,22 2,00 3,50 3,24 3,11 3,12 2,88 3,25 2,88

FECHA 12/04/10
13/04/10 13/04/10 13/04/10 14/04/1014/04/10 15/04/10 15/04/10 15/04/10 16/04/10 16/04/10 16/04/10 16/04/10 16/04/10 17/04/10

HORA 05:00 p.m.
03:00 a.m. 07:00 a.m. 02:00 p.m. 05:00 a.m. 05:00 p.m. 03:00 a.m. 06:30 a.m. 05:00 p.m. 06:40 p.m. 06:00 a.m. 07:00 a.m. 01:40 p.m. 10:00 p.m. 09:30 a.m.

OBSERVACIONES:

ITEM 8 Tromel 1 se encontró 1,77 gpl de concentración de cobre en la muestra final, la operación debe terminar conconcentració menor a 1. ITEM 13 Tromel 3 se encontró 1,92 gpl de concentración de cobre en la muestra final, la operación debe terminar con concentr menor a 1.

Segundo Fernández Jefe de Planta

Ing. Marcos Surco Jefe de Proyectos

HUMEDAD (%)
ÍTEM 1 ESTADO No operativo
No operativo No operativo No operativo No operativo No operativo No operativo No operativo No operativo No operativo Nooperativo No operativo No operativo No operativo No operativo 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

FINAL DE PROCESO [Cu ] (gpl) Menor a 1
Menor a 1 Menor a 1 Menor a 1 Menor a 1 Menor a 1 Menor a 1 1,77 Menor a 1 Menor a 1 Menor a 1 Menor a 1 1,92 Menor a 1 Menor a 1
+2

DESCRIPCIÓN Hidróxido de cobre
Hidróxido de cobre HIdróxido de cobre CROMPTOM Hidróxido de cobre Hidróxido de...