Abma rules for high capacity aseptic bags
Last modified 27/01/2011
A.B.M.A. SPECIFICATION SHEET FOR 200/220 and 800/1000/1400 LITRES ASEPTIC BAGS
-1-
ISSUE 2011
Last modified 27/01/2011
Bags must be compatiblewith the type of filler and the outer packaging used.
Standard Bag Sizes (all internal)
200 and 220 litres (55 and 60 Gall) : 905 (+/- 15) x 1560 (+/- 15) mm, 1‘’ spout, position : centre 150 mm(+/-15) mm distance from inner edge of top seal mode of filling : conveyor belt / horizontal for old and new types of conical drum
200 and 220 litres (55 and 60 Gall) : 905 (+/- 15) x 1560 (+/- 15)mm, 1‘’ spout, position : centre 60-80 mm (+/-15) mm distance from inner edge of top seal mode of filling : direct into drum / vertical for old and new types of conical drum 2060 (+/- 20) x 2160 (+/-20) mm, 1‘’ spout, position : in bag centre (+/-30 mm) for standard bin : Length : 1143 mm, Width : 1041mm, Height : 990 mm (internal)
1000 and 1200 litres (300 Gall) :
1400L ( 330Gal) :
2400(+/- 20) x 2080 (+/- 20) mm, spout, position : in bag centre (+/-30 mm) 2050 (+/- 20) x 1800 (+/- 20) mm, 1‘’ spout, position : in bag centre (+/-30 mm) 1-5 litres (depending on the filler type) Othersizes and films on request
800L :
Lab bag :
Notes : Regarding the above mentioned nominal values, a further +/- 10 mm tolerance is possible. For dispensing applications, where two fitmentsare used, one for filling and one for dispensing, consult with the supplier for the position of the dispensing spout. (Position of the filling spout remains the same as above). Any bag dimension shouldbe checked with the dimension of the outer packaging. Consult the supplier for further details. Aseptic Bags spout location should be checked with the supplier according to the filling headspecifications. For product sampling to customer High Barrier bags should always be used.
-2-
ISSUE 2011
Last modified 27/01/2011
Standard Closures
1) heat resistant types for temperatures max....
Regístrate para leer el documento completo.