Balanza
A Division of eProduction Solutions, Inc.
MODEL #
DESCRIPTION
M2616
FM
APPROVED
“Toledo Style” 744/745/745A Beam
®
Capacities: 500, 1.25K, 2.5K, 5Kand 10K lbs. Included Cable: 20’ Four Conductor Jacketed Cable
TYPICAL APPLICATIONS
• • • Replaces Toledo®/Mastron® 744/745/745A type load cells All stainless steelconstruction Hermetically sealed to withstand harsh environments
SPECIFICATION
Load cell specifications are subject to change without notice.
"H" HOLES
"D" DIA
Output: 2.0mV/V(Nominal) Non-Linearity: 0.02% FSO Hysteresis: 0.05% FSO Zero Balance: ± 1% Comp. Temp. Range: 0° to 150°F Operating Temp. Range: -40° to 180°F Terminal Resistance: 400 OHMSExcitation Voltage: 6-15 VDC Safe Overload: 200%
"A"
"C" .63
"B"
1/4 NPT
load direction
"L"
+
4 CONDUCTOR CABLE SHIELDED & JACKETED x 20 ft LG
CAPACITIES“A”TYP “B” 1.20 1.46 1.68 2.88 3.00 3.75
“C” 1.00 1.00 1.50
“D” 0.63 0.63 0.88
“H”
“L”
FM
APPROVED
INTRINSICALLY SAFE AND NONINCENDIVE FOR CLASS I, II, III, DIV. 1 & 2 GPA-G HAZ. LOCATION PER DWG> 50010 TEMP CODE Ta = 85° C
500, 1.25K & 2.5K 5K 10K
0.500 5.18 0.500 5.38 0.750 6.87
Industrial - Beam Cells
Safety Considerations: Alwaysuse load cells below the specified load rating. Load applied must be in the primary load axis. Extraneous loads or compound stress must be avoided. De-rate load cell maximum load orsupply safety hardware where failure could cause injury or damage. (i.e. safety chains, safety rods, etc.) Do not jerk load or apply load at high rate of speed. Inspect routinelyfor damage, excessive wear or corrosion. Replace if found. Consult a qualified engineer prior to use.
© 2004. Muse Measurements. MTSS06.04. All rights reserved.
Regístrate para leer el documento completo.