Bta-brb
BTA/BTB12 and T12 Series
12A TRIACS
SNUBBERLESS™, LOGIC LEVEL & STANDARD
MAIN FEATURES:
Symbol IT(RMS) VDRM/VRRM IGT (Q1) Value 12 600 and 800 10 to 50 Unit A V mA
A1 A2 G
G
A2
A1
A2
DESCRIPTION Available either in through-hole or surface-mount packages, the BTA/BTB12 and T12 triac series is suitable for general purpose AC switching. They can be used as an ON/OFFfunction in applications such as static relays, heating regulation, induction motor starting circuits... or for phase control operation in light dimmers, motor speed controllers,... The snubberless versions (BTA/BTB...W and T12 series) are specially recommended for use on inductive loads, thanks to their high commutation performances. By using an internal ceramic pad, the BTA series provides voltageinsulated tab (rated at 2500V RMS) complying with UL standards (File ref.: E81734) ABSOLUTE MAXIMUM RATINGS
Symbol IT(RMS) Parameter RMS on-state current (full sine wave)
D2PAK (T12-G)
A2
A1 A2 G
A1 A2 G
TO-220AB Insulated (BTA12)
TO-220AB (BTB12)
Value Tc = 105°C 12 Tc = 90°C t = 20 ms t = 16.7 ms 120 126 78 Tj = 125°C Tj = 25°C Tj = 125°C Tj = 125°C 50 VDRM/VRRM
+ 100
Unit AA
D²PAK/TO-220AB TO-220AB Ins.
ITSM
Non repetitive surge peak on-state current (full cycle, Tj initial = 25°C) I²t Value for fusing Critical rate of rise of on-state current IG = 2 x IGT , tr ≤ 100 ns
F = 50 Hz F = 60 Hz
I ²t dI/dt
tp = 10 ms F = 120 Hz tp = 10 ms tp = 20 µs
A² s A/µs V A W °C 1/7
VDSM/VRSM Non repetitive surge peak off-state voltage IGM PG(AV) Tstg TjPeak gate current Average gate power dissipation Storage junction temperature range Operating junction temperature range
4 1 - 40 to + 150 - 40 to + 125
April 2002 - Ed: 5A
BTA/BTB12 and T12 Series
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise specified)
s
SNUBBERLESS™ and LOGIC LEVEL (3 Quadrants)
Symbol Test Conditions Quadrant T12 T1235 IGT (1) VGT VGD IH (2) IL dV/dt (2)(dI/dt)c (2) VD = 12 V RL = 30 Ω I - II - III I - II - III I - II - III MAX. MAX. MIN. MAX. I - III II VD = 67 %VDRM gate open Tj = 125°C (dV/dt)c = 0.1 V/µs (dV/dt)c = 10 V/µs Without snubber Tj = 125°C Tj = 125°C Tj = 125°C MIN. MIN. MAX. 35 50 60 500 6.5 15 25 30 40 6.5 2.9 35 SW 10 1.3 0.2 35 50 60 500 6.5 50 70 80 1000 12 V/µs A/ms BTA/BTB12 CW 35 BW 50 mA V V mA mA Unit
VD = VDRM RL =3.3 kΩ Tj = 125°C IT = 100 mA IG = 1.2 IGT
s
STANDARD (4 Quadrants)
Symbol Test Conditions Quadrant BTA/BTB12 C IGT (1) VD = 12 V VGT VGD IH (2) IL dV/dt (2) VD = VDRM RL = 3.3 kΩ Tj = 125°C IT = 500 mA IG = 1.2 IGT VD = 67 %VDRM gate open Tj = 125°C Tj = 125°C I - III - IV II MIN. MIN. (dV/dt)c (2) (dI/dt)c = 5.3 A/ms RL = 30 Ω I - II - III IV ALL ALL MAX. MAX. MIN. MAX. MAX. 25 40 80 200 525 50 1.3 0.2 50 50 100 400 10 V/µs V/µs B 50 100 mA V V mA mA Unit
STATIC CHARACTERISTICS
Symbol VT (2) Vto (2) Rd (2) IDRM IRRM
Note 1: minimum IGT is guaranted at 5% of IGT max. Note 2: for both polarities of A2 referenced to A1
Test Conditions ITM = 17 A tp = 380 µs Tj = 25°C Tj = 125°C Tj = 125°C Tj = 25°C Tj = 125°C MAX. MAX. MAX. MAX.
Value 1.55 0.85 35 5 1
Unit V V mΩ µA mAThreshold voltage Dynamic resistance VDRM = VRRM
2/7
BTA/BTB12 and T12 Series
THERMAL RESISTANCES
Symbol Rth(j-c) Rth(j-a) Junction to case (AC) Parameter D²PAK/TO-220AB TO-220AB Insulated Junction to ambient S=1 cm² D²PAK TO-220AB TO-220AB Insulated
S = Copper surface under tab
Value 1.4 2.3 45 60
Unit °C/W
°C/W
PRODUCT SELECTOR
Voltage (xxx) Part Number 600 VBTA/BTB12-xxxB BTA/BTB12-xxxBW BTA/BTB12-xxxC BTA/BTB12-xxxCW BTA/BTB12-xxxSW T1235-xxxG
BTB: non insulated TO-220AB package
Sensitivity 800 V X X X X X X 50 mA 50 mA 25 mA 35 mA 10 mA 35 mA X X X X X X
Type Standard Snubberless Standard Snubberless Logic level Snubberless
Package TO-220AB TO-220AB TO-220AB TO-220AB TO-220AB D²PAK
ORDERING INFORMATION
BT A 12 TRIAC SERIES INSULATION: A:...
Regístrate para leer el documento completo.