Calculo de anclaje
CAlCULO DE ANCLAJE PARA ACCESO PRINCIPAL. NIVEL 2100.
MINA LA PRECIOSA.
DATOS:
SECC. OBRA 3.5 M X 3.5 M
DENSIDAD ROCA = 3.0 TON/M³AREA A ANCLAR = 2450 MTS²
LONGITUD A ANCLAR ( C ) = 490 MTS
Ht = 3.5
W = 3.5
SOPORTE ESTIMADO POR ANCLA ( Wp ) = 14 TON.
LIMITE ELASTICO ANCLA SPLIT SET =2536 KG/CM²
Fs = 4
H = 3.5/ 2,8 = 1.25 MTS B = W + Ht
V = ABC 4,3+4.0 = 8.3 MTS
V =4.3X1.54X30 = 2144 MTS³ D = 1/5 B
T =198 X 2.8 = 6003 TON 1.66 MTS
V = ABC
6003 TON / 20 TONXANCLA = 353 ANCLAS 4,3X1,66X30 214 MTS³
T = 214 X 2,8 600 TON.
600 TON / 20TONXANCLA = 30
ANCLAS
PROMEDIO= 28 + 30 =58
29 ANCLAS
SEPARACION ENTRE ANCLAS.
AREA TOTAL = 2450 M² / 2362 ANCLAS = 1.03 M²/ANCLA. A = π D²/4 ; 1.03M² = 3,1416D²/4 ; D² = 1.27 M²
D = 1.27 M² D = 1.12
SEPARACION ENTRE ANCLAS 1.0 M X 1.0 M
HOJA 1
CALCULO PARA SUELOARCILLOSO.
LONGITUD DE ANCLA :
DATOS:
Wb = CAPACIDAD ANCLA = 20TON
T = ANCHO A ANCLAR = 4,3 MTS Wb = δ x T x C x L
δ = DENSIDADROCA = 2,8 TON/M³ ( N1 + 1) ( N2 + 1)
L = LONGITUD ANCLA ?
N1 = NUMERO DE FILAS = 3
N2 = NUMERO DE ANCLAS POR FILA = 10 L = 880 TON
C = LONGITUD A ANCLAR = 30 MTS 361TON/M
LONGITUD ANCLA = 2.5 MTS.
AREA DEL ACERO: SI SE CONOCE QUE EL LIMITE ELASTICO DEL ACERO ESTA RELACIONADO
CON EL SOPORTE DEL ANCLA.TENDREMOS:
T = As.Fy
Fy = LIMITE ELASTICO DEL ACERO X Fs = 2536 kg/cm² x 4 = 10144 kg/cm²
As = Wb / Fy = 20000 kg/10144 kg/cm² = 1,97...