Catalogo reglas opticas
Mechanical Specifications Case Measuring element Operating principle Dimensions Total dimensions Grating pitch Reading resolution after the external electronic quadruplingProtections Accuracy (at 20°C) Max. speed Max. acceleration Thermal expansion Vibration resistance (10÷2000 Hz) Shock resistance (11 ms) Operating temperature Stocking temperature Protection degreeElectrical Specifications Zero pulse Supply Output signals Electronic outputs Connections
KD10
KD100
KD200
KD1000
extrused aluminium out of stainless steel with thermal compensationphotoelectric reading by reflection 23 x 56.7 mm stroke + 150 mm 400 µm 40 µm 20 µm 40 µm with inside divider by 10 0.1 mm 0.01 mm 0.005 mm 0.001 mm anti-oil double gum sealing ± 0.010 mm/m ± 0.005 mm/m ±0.003 mm/m ±0.003 mm/m 120 m/min 80 m/min 60 m/min 25 m/min 2 2 2 2 40 m/sec. 30 m/sec. 30 m/sec. 25 m/sec. ppm/°C/m = ± 10.6 T rif.20°C ±0.1°C 2 100 m/sec. 2 150 m/sec. 0÷50 °C relative humidity 20-80%-20÷70 °C standard IP54, pressured type IP64
KD10 KD100 KD200 KD1000 1 zero reference at half measuring length (other positions on request)- type 1Z standard: 12Vdc - 40 mA / on request: 5 Vdc 65mA 5Vdc 65mA 2 square waves 90° degree out of phase NPN pull-up collector/ optional 5 Vdc line driver 5Vdc line driver standard cable with metal sheat 4 mt long
Automática Electrónica y Control,S.L. Gorina i Pujol, 61 - 08203 Sabadell (Barcelona) Tel 902 900 765 Fax 937 209 999 www.automatica-elec.es info@automatica-elec.es
OPTICAL READERS SERIES KD Mechanical Dimensions
Optical...