Celulas De Carga
Special features
− 4 limit switches with hysteresis − Dosing functionalities and diagnostic channel (Type E) − High overload limits − Degree of protection IP67 − Fast triggering and scaling of the measured value − Trigger function (external or level trigger) − Test report for 3000 d accord. to OIML R 60, R 76
Dimensions (in mm; 1 mm = 0.03937inches)
114 ±0.2 ∅ 20 4H7 6.2 50−0.2 25
60
44 ±0.1
22 ±0.2
∅ 19 ±0.1 ∅ 32
M6; Tightening torque 10 N⋅m Max. screw-in depth: 7 mm Recommend. flatn. of plate: 0.1 mm
14
149 20 16 6 26.5
17.5
25
60
5 5
B1716-2.0 en
7−0.05
Data Sheet
FITR/0...
The FIT/... digital load cells are available in different versions, e.g.:
1FIT/ 0 E B 3 0/ 5 KG Max. capacity:Cable length: Accuracy class: Interfaces: Version: Housing: Designation: 5, 10, 20, 50, 75 kg 0 = with plug 3 = C3 A = RS-232, B = RS-485, C = CANOpen, D = DeviceNet S = Standard, E = Extended 0 = without housing FIT
HBM has defined so-called preferred variants. All other variants are available on request.
Preferred variants of the standard types
Housing RS-232 FIT/0 1-FIT/0SA30/5KG1-FIT/0SA30/10KG 1-FIT/0SA30/20KG 1-FIT/0SA30/50KG 1-FIT/0SA30/75KG 1-FIT/1SA31/5KG 1-FIT/1SA31/10KG 1-FIT/1SA31/20KG 1-FIT/1SA31/50KG 1-FIT/1SA31/75KG RS-485 (4 wire) 1-FIT/0SB30/5KG 1-FIT/0SB30/10KG 1-FIT/0SB30/20KG 1-FIT/0SB30/50KG 1-FIT/0SB30/75KG 1-FIT/1SB31/5KG 1-FIT/1SB31/10KG 1-FIT/1SB31/20KG 1-FIT/1SB31/50KG 1-FIT/1SB31/75KG 1-FIT/1SB32/5KG 1-FIT/1SB32/10KG 1-FIT/1SB32/20KG 1-FIT/4SB32/5KG1-FIT/4SB32/10KG 1-FIT/4SB32/20KG 1-FIT/5SA30/5KG 1-FIT/5SA30/10KG 1-FIT/1SA30/20KG 1-FIT/5SC30/5KG 1-FIT/5SC30/10KG Interface CANOpen 1-FIT/0SC30/5KG 1-FIT/0SC30/10KG DeviceNet 1-FIT/0SD30/5KG 1-FIT/0SD30/10KG
FIT/1
1-FIT/1SC31/5KG 1-FIT/1SC31/10KG
1-FIT/1SD31/5KG 1-FIT/1SD31/10KG
FIT/4
FIT/5
Preferred variants of the extended types In addition to the standard version (S), another extendedversion (E) with control functions (two connecters) is available. All versions offers additional application areas with limit values and dosing control functions (sorting systems, filling systems).
Housing RS-232 FIT/0 1-FIT/0EA30/5KG 1-FIT/0EA30/10KG 1-FIT/0EA30/20KG 1-FIT/0EA30/50KG 1-FIT/0EA30/75KG 1-FIT/1EA31/5KG 1-FIT/1EA31/10KG 1-FIT/1EA31/20KG 1-FIT/1EA31/50KG 1-FIT/1EA31/75KG − RS-485 (4wire) 1-FIT/0EB30/5KG 1-FIT/0EB30/10KG 1-FIT/0EB30/20KG 1-FIT/0EB30/50KG 1-FIT/0EB30/75KG 1-FIT/1EB31/5KG 1-FIT/1EB31/10KG 1-FIT/1EB31/20KG 1-FIT/1EB31/50KG 1-FIT/1EB31/75KG 1-FIT/4EB31/5KG 1-FIT/4EB31/10KG 1-FIT/4EB32/5KG 1-FIT/4EB32/10KG 1-FIT/5EB30/5KG 1-FIT/5EB30/10KG Interface CANOpen 1-FIT/0EC30/5KG 1-FIT/0EC30/10KG DeviceNet 1-FIT/0ED30/5KG 1-FIT/0ED30/10KG
FIT/1
1-FIT/1EC31/5KG1-FIT/1EC31/10KG
1-FIT/1ED31/5KG 1-FIT/1ED31/10KG
FIT/4
1-FIT/4EC31/5KG 1-FIT/4EC31/10KG
1-FIT/4ED31/5KG 1-FIT/4ED31/10KG
FIT/5
1-FIT/5EA30/5KG 1-FIT/5EA30/10KG
1-FIT/5EC30/5KG 1-FIT/5EC30/10KG
1-FIT/5ED30/5KG 1-FIT/5ED30/10KG
= for these load cell types separate data sheets are available
HBM
2
B1716-2.0 en
Specifications
Type Accuracy class according to OIMLR60 Max. capacity (Emax) Min. load cell verification interval (vmin) Min. application range for 3000 d Max. platform size Max. number of load cell verification intervals (nLC) Apportionment factor (pLC) Temperature effect on sensitivity (TKC)1) 2) in temperature range 0 5C...+40 5C [32 5F...+104 5F] Temperature effect on zero signal (TKS0)2) Hysteresis factor (dhy)1) 2)" Nonlinearity (dlin)1) 2)"Creep (dCR) over 30 min" Eccentric loading error acc. to OIML R76 Service load (EU); max. 120 mm eccentricity Safe load limit (EL); max. 20 mm eccentricity Permissible dyn. load (Fsrel) max. 50 mm eccentricity Deflection at max. capacity (snom) Power supply: Supply voltage UB1 (DC) Power consumption Switch-on current Resolution of meas. signal (1 Hz-Filter) Measuring rate Adjustable cut-off...