Chiller
INSTRUCTION MANUAL • INSTALLATION • OPERATION • MAINTENANCE
Covering models from 1/4 to 1.5 tons with the IC-5 Chiller Control
ADVANTAGE ENGINEERING, INC. 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277 Service Department fax: 317-885-8683 www.AdvantageEngineering.com e-mail: service@AdvantageEngineering.com
INSTRUCTION MANUAL
IC-5CHILLER CONTROL AIR & WATER-COOLED MODELS
COVERING
INSTALLATION OPERATION MAINTENANCE
ADVANTAGE ENGINEERING, INC. 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277 Service Department fax: 317-885-8683 website: www.AdvantageEngineering.com e-mail: service@AdvantageEngineering.com
Maximum Series Portable Chiller : Air & Water-Cooled : IC-5 Chiller Control
TABLEOF CONTENTS 1.0 GENERAL 1.1 Introduction 1.2 Unit location 1.3 Efficiency 1.4 Safety 1.5 Clean air act 1.6 Miscellaneous 1.7 Water treatment 1.8 Components INSTALLATION 2.1 General 2.2 To and From process connections 2.3 Water supply connection 2.4 Air-cooled condenser 2.5 Water-cooled condenser 2.6 Electrical connection OPERATIONS 3.1 General 3.2 Start up/operations procedure 3.3Instrument/operation 3.4 Shut down procedure TROUBLESHOOTING 4.1 Unit Will Not Start 4.2 Compressor Hums But Will Not Start 4.3 Shuts Off On High Pressure 4.4 Shuts Off On Low Pressure 4.5 Compressor Shuts Off On Internal Overload 4.6 Low Or No Process Pressure Or Water Flow 4.7 Cooling Capacity Inadequate 4.8 Sensor 4.9 Coolant Pump 4.10 Crankcase Heater 4.11 Chiller Controller MAINTENANCE 5.1 Warranty serviceprocedure 5.2 Periodic preventative maintenance 5.3 Special maintenance 5.4 Checking the refrigerant charge 7 8 8 8 9 9 9 9 10 11 12 12 13 13 14 14 17 18 19 21 24 27 28 28 28 28 29 29 30 30 30 31 31 33 34 35 35 35
2.0
3.0
4.0
5.0
Page: 4 ADVANTAGE ENGINEERING, INC. 525 East Stop 18 Road Greenwood, Indiana 46142 317-887-0729 Fax: 317-881-1277 Service Department Fax: 317-885-8683Email: service@AdvantageEngineering.com
Maximum Series Portable Chiller : Air & Water-Cooled : IC-5 Chiller Control
6.0
COMPONENTS 6.1 Water system 6.2 Refrigeration system RELATED DRAWINGS 7.1 Typical Electrical : Air-Cooled 7.2 Mechanical Schematic APPENDIX 8.1 Operations below 48°F 8.2 Water quality control 8.3 Inhibited propylene glycol 8.4 Sensor current vs temperature 8.5Pressure-temperature chart 8.6 Chiller capacity and derate chart 8.7 Reverse flow model installation
37 38 38 41 42 43 45 46 49 47 47 48 49 50
7.0
8.0
Page: 5 ADVANTAGE ENGINEERING, INC. 525 East Stop 18 Road Greenwood, Indiana 46142 317-887-0729 Fax: 317-881-1277 Service Department Fax: 317-885-8683 Email: service@AdvantageEngineering.com
THIS PAGE INTENTIONALLY BLANK
Page: 6
MaximumSeries Portable Chiller : Air & Water-Cooled : IC-5 Chiller Control
1.0
GENERAL
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 INTRODUCTION UNIT LOCATION EFFICIENCY SAFETY CLEAN AIR ACT MISCELLANEOUS WATER TREATMENT COMPONENTS
Page: 7 ADVANTAGE ENGINEERING, INC. 525 East Stop 18 Road Greenwood, Indiana 46142 317-887-0729 Fax: 317-881-1277 Service Department Fax: 317-885-8683 Email:service@AdvantageEngineering.com
Maximum Series Portable Chiller : Air & Water-Cooled : IC-5 Chiller Control
1.1
INTRODUCTION A. B. This manual covers portable chillers from 1/4 to 1.5 tons. When calling for assistance from the Manufacturer’s Service Department, it is important to know the model and serial number of the particular unit. The model number encodes critical unit information which is helpful inany attempt to troubleshoot operating difficulties. The serial number allows the service team to locate manufacturing and testing records which can have additional information relating to a particular unit.
1.2
UNIT LOCATION A. For air-cooled and water-cooled models: 1. 2. B. These units are designed for indoor use only. For most efficient operation, locate the chiller in a clean, dry and...
Regístrate para leer el documento completo.