circulo de morh

Páginas: 5 (1150 palabras) Publicado: 29 de enero de 2014
INSTALACIONES ELECTRICAS

APENDICE DE TABLAS

INDICE
TABLA 9 (NEC)…………………………………………………………………………………………………… 2
RELEVADORES MONTADOS POR SEPARADO…………………………………………………………….. 3
ELEMENTO TERMICO BIMETALICO……………………………………………………………………….. 4
NIVELES DE AISLAMIENTO NORMALIZADOS PARA EQUIPO DE LA CATEGORÍA "A"………….5
NIVELES DE AISLAMIENTO NORMALIZADOS PARA EQUIPO DE LA CATEGORÍA "B"………….6
NIVELES DEAISLAMIENTO NORMALIZADOS PARA EQUIPO DE LA CATEGORÍA "C"………….7
CARACTERÍSTICAS DE PROTECCIÓN DE APARTARRAYOS TIPO ESTACIÓN..........................…… 8
CARACTERÍSTICAS DE PROTECCIÓN DE APARTARRAYOS TIPO INTERMEDIO…………………10
CARACTERÍSTICAS DE PROTECCIÓN DE APARTARRAYOS TIPO DISTRIBUCIÓN……………….11


RESISTENCIA Y REACTANCIA PARA CABLES DE 600 VOLTS, 60 C.P.S. Y 75 ºC


TABLA 9 RELEVADORESMONTADOS POR SEPARADO
ELEMENTO TERMICO BIMETALICO

PARA USARSE CON
CORRIENTE
A PLENA CARGA
NUMERO DE ELEMENTO
CORRIENTE
A PLENA CARGA
NUMERO DE ELEMENTO
CORRIENTE
A PLENA CARGA
NUMERO DE ELEMENTO
CORRIENTE
A PLENA CARGA
NUMERO DE ELEMENTO
CORRIENTE
A PLENA CARGA
NUMERO DE ELEMENTO
CLASE
TIPO
TAMAÑO










9065
ARG






ARO
25 AMP
0.33 - 0.35
AR 45
0.76- 0.83
AR 105
1.78-1.96
AR 246
4.21 - 4.62
AR 50
9.94 - 10.9
AR 136



0.36 - 0.39
AR 49
0.84 - 0.91
AR 115
1.97 - 2.16
AR 271
4.63 - 5.00
AR 64
11.0 - 12.4
AR 154



0.40-0.42
AR 54
0.92 -1.00
AR 126
2.17 - 2.37
AR 298
5.09 - 5.57
AR 70
12.5 - 14.3
AR 176







0.43 - 0.46
AR 59
1.01-1.10
AR 139
2.38 - 2.62
AR 328
5.58 - 6.13
AR 77
14.4 - 15..8AR 205



0.47 - 0.51
AR 65
1.11 -1.21
AR 153
2.63 - 2.88
AR 362
6.14 - 6.83
AR 85
15.9 - 17.9
AR 23



0.52 - 0.56
AR 71
1.22 -1.33
AR 168
2.89 - 3.17
AR 398
6.84 - 7.41
AR 97
18.0 - 20.0
AR 27







0.57 - 0.62
AR 78
1.34 -1.47
AR 185
3.18 - 3.48
AR 437
7.42 - 8.05
AR 102
20.1 - 22.4
AR 30



0.63 - 0.68
AR 86
1.48 -1.62
AR 204
3.49 - 3.83
AR480
8.06 - 8.98
AR 112
22.5 - 25.0
AR 35



0.69 - 0.75
AR 95
1.63 -1.77
AR 224
3.84 - 4.20
AR 53
8.99 - 9.93
AR 124





ATG

ATO
50 AMP
6.84 - 7.49
AR 93
10.0 - 11.1
AR 136
16.7 - 19.3
AR 23
28.4 - 31.2
AR 40
38.6 - 41.5
AR 55



7.50 - 8.05
AR 102
11.2 - 12.7
AR 154
19.4 - 21.4
AR 27.
31.3 - 33.3
AR 44.
41.6 - 45.0
AR 60



8.06 - 9.10
AR 11212.8 – 14.8
AR 176
21.5 - 25.1
AR 30
33.4 - 35.7
AR 47





9.11 - 9.99
AR 124
14.9 - 16.6
AR 205
25.2 - 30.3
AR 35
35.8 - 38.5
AR 51





AUG

AUO
100 AMP
14.4 - 16.1
AU 20
21.5 - 26.9
AU 33
35.1 - 38.8
AU 50
55.6 - 60.0
AU 61





16.2 - 18.6
AU 23
27.0 - 28.3
AU 38
38.9 - 44.3
AU 56
61.1 - 68.6
AU 80





18.7 - 20.5
AU 26
28.4 - 30.8AU 40
44.4 - 49.3
AU 64
68.7 - 76.3
AU 99





20.6 - 23.4
AU 29
30.9 - 35.0
AU 44
49.4 - 55.5
AU 72
76.4 - 86.0
AU 110





AFG

AFO
150 AMP
42.0 - 46.4
AU 50
57.2 - 63.7
AU 72
77.4 - 82.2
AU 99
99.4 - 113
AU 135





46.5 - 51.4
AU 56
63.8 - 69.0
AU 81
82.3 - 92.8
AU 110
114 - 123
AU 152





51.5 - 57.1
AU 64
69.1 - 77.3
AU 88
92.9 - 99.3AU 123
124 -133
AU 169





AGG
AGO
300 AMP
90.6 - 97.4
AF 110
112 - 129
AF 135
150 -163
AF 159.
190 - 213
AF 188
241 - 266
AF 220



97.5 - 111
AF 121
130 - 149
AF 150
164 - 189
AF 168
214 - 240
AF 205






TABLA 4. NIVELES DE AISLAMIENTO NORMALIZADOS PARA EQUIPO DE LA CATEGORÍA "A".
Tensión nominal
del sistema.
KV (eficaz)
Tensión máxima
dediseño.
KV (eficaz)
Nivel básico de aislamiento al
impulso (NBI) de fase a tierra.
KV (cresta)
Tensión resistente
nominal a 60 Hz de
fase a tierra.

KV (eficaz)


Hasta
500 KVA
Arriba de 500
KVA

4.41)
4.4
60
75
19
6.91)
7.2
75
95
26
13.82)
15.5
95
110
34
242)
26.4
1504)
50
34.52)
38
2005)
70
523)
52
250
95


Notas:

1) Tensiones congeladas según...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • circulo de morh
  • Circulo De Morh
  • Circulo De Morh
  • circulo de morh
  • Circulo de morh
  • circulo de morh
  • Circulo De Morh
  • circulo de morh

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS