Display 2X16
Features
1. 2. 3. 4. 5. 5x8 dots Built-in controller (S6A0069 or equivalent) +5V power supply 1/16 duty cycle LED Backlight
SPECIFICATIONS OF LCD MODULE
Outline dimension
Unit: mm
Absolute maximum ratings
Item Power voltage Input voltage Operating temperature range Storage temperature range Environmental Humidity Expected Life Time Symbol VDD-VSS VIN Top Tst Standard 0 7.0VSS VDD 0 +50 -10 +60 RH≤70% ≥50000 Unit V ℃ H
Wide temperature range is available (operating/storage temperature as –20~+70/-30~+80 )
GDM2004D-FL-YBW Block diagram
VDD VSS V0 RS R/W E DB0-DB7 R LED BKL COM
LCD PANEL
LCD CONTROLLER AND DRIVER
SEG SEG
LCD DRIVER
LED+ LED-
Interface pin description
Pin no.
1 2 3 4 5 6 7~10 11~14 15 16
Symbol VSS VDD V0
RS R/W E DB0~DB3DB4~DB7 LED+ LED-
External connection
Power supply MPU MPU MPU MPU MPU LED BKL power Supply
Function
Signal ground for LCM (GND) Power supply for logic (+5V) for LCM Contrast adjust Register select signal Read/write select signal Operation (data read/write) enable signal Four low order bi-directional three-state data bus lines. Used for data transfer between the MPU and the LCM. Thesefour are not used during 4-bit operation. Four high order bi-directional three-state data bus lines. Used for data transfer between the MPU Power supply for BKL (Anode) Power supply for BKL (GND)
Contrast adjust
A)For Single Source
For Module with Normal Temperature Range Fluid VDD~V0: LCD Driving voltage
VR: 10k~20k
VER 1.0
2/9
2003/12/09
GDM2004D-FL-YBW
Opticalcharacteristics
STN type display module (Ta=25℃, VDD=5.0V)
Item Viewing angle Contrast ratio Response time (rise) Response time (fall)
Symbol θ Φ Cr Tr Tr
Condition Cr≥2 -
Min. -60
-40
-
Typ. 15 150 150
Max. 35 40 250 250
Unit deg ms
Electrical characteristics LED ratings
Item Forward Voltage Forward current Power Peak wave length Luminance Operating temperature range Storagetemperature range DC characteristics Parameter
Supply voltage for LCD Input voltage Backlight supply voltage Supply current Backlight supply current Input leakage current “H” level input voltage “L” level input voltage “H” level output voltage “L” level output voltage
Symbol VF IF P λp Lv VOP VST
Min 3.8
Typ. 4.0 240 568 185 -
Max 4.4 1.01
Unit V mA W nm Cd/m2 ℃
-20 -25
+70 +80Symbol VDD-V0 VDD VF IDD IF ILKG VIH VIL VOH VOL
Conditions
Ta =25℃
Min.
4.7 150 2.2 0 2.4 -
Typ.
4.6 4.1 1.5 -
Max.
5.5 4.3 3 1.0 VDD 0.6 0.4
Unit
V
Ta=25℃, VDD=5.0V VDD=5.0V R=6.8
mA uA V
Twice initial value or less LOH=-0.25mA LOH=1.6mA
Read cycle (Ta=25℃, VDD=5.0V)
Parameter
Enable cycle time Enable pulse width Enable rise/fall time RS; R/W setup time RS;R/W address hold time Read data output delay Read data hold time
Symbol tc tw tr, tf tsu th td tdh
Test pin
E RS; R/W RS; R/W DB0~DB7
Min.
500 300 100 10 60 20
Typ.
-
Max.
25 90 -
Unit
ns
VER 1.0
3/9
2003/12/09
GDM2004D-FL-YBW Write cycle
Parameter
Enable cycle time Enable pulse width Enable rise/fall time RS; R/W setup time RS; R/W address hold time Read dataoutput delay Read data hold time
Symbol tc tw tr, tf tsu1 th1 tsu2 th2
Test pin
E RS; R/W RS; R/W DB0~DB7
Min.
500 300 100 10 60 10
Typ.
-
Max.
25 -
Unit
ns
Write mode timing diagram
Read mode timing diagram
VER 1.0
4/9
2003/12/09
GDM2004D-FL-YBW
Instruction description
Outline
To overcome the speed difference between the internal clock of KS0066Uand the MPU clock, KS0066U performs internal operations by storing control in formations to IR or DR. The internal operation is determined according to the signal from MPU, composed of read/write and data bus (Refer to Table7). Instructions can be divided largely into four groups: 1) KS0066U function set instructions (set display methods, set data length, etc.) 2) Address set instructions to...