Dnp-21 Conector
FBP FieldBusPlug
V6
DeviceNet FieldBusPlug DNP21-FBP
DeviceNet
DNP21-FBP DeviceNet FieldBusPlug Technical Description
Please note the following
Target group This description is intended for the use of trained specialists in electrical installation and control and automation engineering, who are familiar with the applicable national standards. Safetyrequirements The responsible staff must ensure that the application or use of the products described satisfy all the requirements for safety, including all the relevant laws, regulations, guidelines and standards.
V6
DNP21-FBP
-2-
FieldBusPlug / Issue: 07.2007
DNP21-FBP DeviceNet FieldBusPlug V6 Technical Description
ContentOverview..................................................................................................................................................5 Purpose and short description..............................................................................................................5 Connector pin assignment ....................................................................................................................7 Indicators andoperating elements on the front plate ........................................................................8 Mapping of I/O data and diagnosis data ..............................................................................................9 For non-modular devices, e.g. MFI21-FBP, UMC22-FBP ..................................................................9 For modular devices, e.g. S500..........................................................................................................9 Integrating a DNP21-FBP with a connected FBP device in RSNetWorx (Rockwell Software) ......10 1. Loading the EDS files of the FBP devices to be connected .........................................................10 2. Configuring the FBP devices on the DeviceNet...........................................................................12 3. Adding the bus master to the scan list .........................................................................................16 Integrating a DNP21-FBP with a connected FBP device in SYCON.net - .......................................19 1. Loading the EDS...........................................................................................................................19 2. Master and bus settings ..............................................................................................................21 3. Slave parameters ..........................................................................................................................22 4.Download......................................................................................................................................24 DeviceNet definitions ...........................................................................................................................25 DeviceNet information to the properties of the DNP12-FBP............................................................27 General information..........................................................................................................................27 Message types .................................................................................................................................27 Class services ...................................................................................................................................27 Object classes..................................................................................................................................27 Class Code 001 (0x01): Identity Object ............................................................................................28 Class Code 002 (0x02): Message Router Object .............................................................................28 Class Code 003 (0x03):...
Regístrate para leer el documento completo.