Dtmf Señalisación
DTMF
Annex to TSW200E1's Operation Manual
Version: 1
Revision: 2
December/2008
Copyright
This manual was created by the Wise Telecommunications Industry team.
No part or contents of this manual can be reprinted without written authorization of Wise
Telecommunications Industry.
Wise Telecommunications Industry reserves itself the right to alter its products, andthe manual
contents, at any time, without any prior warning, according to its own needs.
As the Wise Telecommunications Industry products are under constant development, some
characteristics may not be included in the manuals; they can be added as annexes.
Any contribution or criticism that can better this product or manual will be welcomed by the
company team.
If this manual contents arenot according to the version of the equipment or its operation, please
contact the company, using the phone/fax:
55-61-3486-9100
or the e-mail:
wise@wi.com.br
Wise Telecommunications Industry
Commercial Department:
Setor de Indústria Bernardo Sayão
SIBS quadra 01 conjunto D lote 12
Núcleo Bandeirante – Brasília – DF – Brazil CEP 71736-104
Please visit our homepage: http://www.wi.com.brSummary
1 - Introduction.....................................................................................................................................1
2 - DTMF Module Operation...............................................................................................................2
2.1 - DTMF testConfiguration........................................................................................................2
2.2 - Performing the DTMF test......................................................................................................3
DTMF
1 - Introduction
The TSW200E1 DTMF Module allows simulating the process of calling an end user using
DTMF. The digits can be manually inserted using the equipment keyboard or automatically by
means of auser-selectable number of up to 16 digits. The user can also edit the CAS pattern used
and the following tone characteristics: active time, interval time between tones and tone level. The
only interface used in this module is the G703-2M.
Wise Telecommunications Industry
1
DTMF
2 - DTMF Module Operation
2.1 -
DTMF test Configuration
The configuration of this module is very simple andconsists of two screens. To navigate
between the two screens, use the (BACK) key or (NEXT) key. The (MODULE)
key returns to the module screen.
After selecting the DTMF module at the module screen, the first configuration screen is
shown, as displayed in the figure below. At this screen, the user programs the line parameters. To
modify any parameters, move the cursor up to the parameter linethat is to be changed and use the
← and → keys to modify the parameters.
DTMF
PCM:
Termination:
Line Code:
Polarity:
Channel:
PCM30C
75 Ohms UNBAL
HDB3
NORMAL
30
MODULE
F1
•
•
•
•
•
F2
NEXT
F3
F4
PCM: Selects the frame structure. The structures are PCM30 and PCM30C.
Termination: The cable termination impedance can be chosen as 75 ohms UNBAL,
120 ohmsBAL, HIGH-Z UNBAL or HIGH-Z BAL.
Line Code: Allows choosing the line code as HDB3 or AMI.
Polarity: Selects the polarity signal as NORMAL, where the selected pattern bits are
transmitted normally or INVERTED, where the bits are inverted.
Channel: Channel in which the equipment will initiate the calls.
The next configuration screen, shown in the following figure, selects the parameters for thetransmitted tones and CAS signalization.
Wise Telecommunications Industry
2
DTMF
DTMF
Speed Dial:
On hook:
Off Hook:
DTMF Level:
DTMF On:
DTMF Off:
BACK
F1
•
•
•
•
•
•
2.2 -
1234567890#*1234
0101
0111
-08 dBm
200 ms
100 ms
MODULE
F2
F3
F4
Speed Dial: It is a sequence of up to 16 digits (including numbers from 0 to 9, * and
#) that...