* Condition: the Pack Outlet temperature is excessive. The crew has selected standby to acqire manual control of the pack output temperature. The INOP light remains illuminated. What is the system fault?
* Excessive high pack outlet temperature.
* Automatic Temperature Controller.
* If the Pack outlet temperature becomes excessive, will the PACK OFF lightilluminate in the Reset switch?
* No.
* Yes.
Purpose of recirculating cabin air is to maintain the desired level of passenger cabin ventilation while minimizing the use of bleed air.
False
True
* Altitude setting should be made on LDG ALT during the Cockpit Preparation?
* 200 ft below take-off airport elevation
* Destination airport elevation
* Cabin altitudeas determined from placard
* The Left recirculation fan draws air through the forward E/E system and returns it to the mix manifold
* True.
* False.
* If a Pack Outlet temperature is excessive, how will the crew know if the fault is with automatic pack temperature controller?
* The INOP light remains illuminated upon selection of the Standby Mode.
* The INOP lightextinguished upon selection of the Standby mode.
* Since the Packs operate to maintain the temperature of the cabin zone requiring the lowest temperature, how are the other zones maintained at their desired temperature?
* Trim air is added to the air delivered to the other zones.
* The Packs modulate to deliver warm air to the other zones.
The Left recirculation fan should NOT beturned off as this causes the overboard exhaust valve to latch open. Maintenance action is required to reset this valve.
True
False
-------------------------------------------------
Principio del formulario
Final del formulario
* When there is a failure of the automatic pack temperature controller, the temperature control valve ______.
* Moves to the full cold position.
*Remains in the existing position.
* Moves to the full warm position.
* The airplane is climbing thru 20000 ft, airspeed is 290 kt & pressurization is being automatically controlled. What is the cabin altitude rate of change base on?
* A rate proportional to airplane rate of climb
* A rate based on indicated airspeed
* A rate based on transition altitude
* A rate based ontrue airspeed
* What limits are set by the AUTO RATE control ?
* Cruise altitude
* Differential pressure
* Cabin rates of climb & descent
Automatic pressurization control for a flight requires selection of AUTO 1 or 2, desired AUTO RATE and setting, of LDG ALT.
False
True
Can the APU bleed air be used for cargo heat?
No
Yes
* What type ofpower is used for outflow valve actuation during auto control ?
* DC and AC
* AC
* DC
* When is the alternate auto controller self-tested?
* After engine start
* After landing
* During cruise
* Cooling air circulation for the E/E components & cockpit instrument panels is produced by:
* A duct from the left A/C pack
* A supply and exhaust fan
*Thermal circulation
* During automatic temperature control, which tempertaure zone controls the output of the air conditioning packs?
* The zone with the warmest section
* The zone requiring the warmest air
* The zone requiring the coolest air
* What condition turns the equipment cooling VALVE light on?
* Equipment cooling valve(s) incorrectly positioned
* No airflow inthe equipment cooling system
* Overheat in the equipment cooling system
* Forward equipment cooling supplies cooling air to the equipment in the ______ and the ______.
* None of the above.
* Forward and rear cargo bays - Flightdeck
* Forward cargo hold - Flight deck avionics
* Forward equipment racks - Flight deck avionics
What is the indication of a cargo...