* Condition: the Pack Outlet temperature is excessive. The crew has selected standby to acqire manual control of the pack output temperature. The INOP light remains illuminated. What is the system fault?
* Excessive high pack outlet temperature.
* Automatic Temperature Controller.

* If the Pack outlet temperature becomes excessive, will the PACK OFF lightilluminate in the Reset switch?
* No.
* Yes.

 Purpose of recirculating cabin air is to maintain the desired level of passenger cabin ventilation while minimizing the use of bleed air.
 False
 True

* Altitude setting should be made on LDG ALT during the Cockpit Preparation?
* 200 ft below take-off airport elevation
* Destination airport elevation
* Cabin altitudeas determined from placard

* The Left recirculation fan draws air through the forward E/E system and returns it to the mix manifold
* True.
* False.

* If a Pack Outlet temperature is excessive, how will the crew know if the fault is with automatic pack temperature controller?
* The INOP light remains illuminated upon selection of the Standby Mode.
* The INOP lightextinguished upon selection of the Standby mode.

* Since the Packs operate to maintain the temperature of the cabin zone requiring the lowest temperature, how are the other zones maintained at their desired temperature?
* Trim air is added to the air delivered to the other zones.
* The Packs modulate to deliver warm air to the other zones.

 The Left recirculation fan should NOT beturned off as this causes the overboard exhaust valve to latch open. Maintenance action is required to reset this valve.
 True
 False
-------------------------------------------------
Principio del formulario
Final del formulario
* When there is a failure of the automatic pack temperature controller, the temperature control valve ______.
* Moves to the full cold position.
*Remains in the existing position.
* Moves to the full warm position.

* The airplane is climbing thru 20000 ft, airspeed is 290 kt & pressurization is being automatically controlled. What is the cabin altitude rate of change base on?
* A rate proportional to airplane rate of climb
* A rate based on indicated airspeed
* A rate based on transition altitude
* A rate based ontrue airspeed

* What limits are set by the AUTO RATE control ?
* Cruise altitude
* Differential pressure
* Cabin rates of climb & descent

 Automatic pressurization control for a flight requires selection of AUTO 1 or 2, desired AUTO RATE and setting, of LDG ALT.
 False
 True
 Can the APU bleed air be used for cargo heat?
 No
 Yes
* What type ofpower is used for outflow valve actuation during auto control ?
* DC and AC
* AC
* DC

* When is the alternate auto controller self-tested?
* After engine start
* After landing
* During cruise

* Cooling air circulation for the E/E components & cockpit instrument panels is produced by:
* A duct from the left A/C pack
* A supply and exhaust fan
*Thermal circulation

* During automatic temperature control, which tempertaure zone controls the output of the air conditioning packs?
* The zone with the warmest section
* The zone requiring the warmest air
* The zone requiring the coolest air

* What condition turns the equipment cooling VALVE light on?
* Equipment cooling valve(s) incorrectly positioned
* No airflow inthe equipment cooling system
* Overheat in the equipment cooling system

* Forward equipment cooling supplies cooling air to the equipment in the ______ and the ______.
* None of the above.
* Forward and rear cargo bays - Flightdeck
* Forward cargo hold - Flight deck avionics
* Forward equipment racks - Flight deck avionics

 What is the indication of a cargo...