Estudio de suelos
CLIENTE: | | CRISTIAN C. | CUELLO | | | | |
PROYECTO: | CONSULTORIA | TECNICA | | | | |
LUGAR DEL MUESTREO: | MUNICIPIO | PONEDERA | ATLANTICO | | |
MUESTRA No: 1 | | | | | | |
PRUEBA DE GRADACION |
|
PATRON No 1 1586 | PATRON No 2 1404 | | |
| || |
TAMIZ | | % RETEN | % ACUM | % PASA | INF. | SUP. |
PULG. | MM | RETEN | | | | | |
| | | | | | | |
| | | | | | | |
| | | | | | | |
2 1/2" | 63 | | | | | | |
2" | 50 | | | | | | |
1 1/2" | 38.1 | | | | | | |
1" | 25 | | | | | | |
1/2" | 12.5 | | | | | | |3/8" | 9.5 | | | | | | |
No 4 | 4.75 | | | | | | |
No 10 | 2 | 0.00 | 0.00 | 0.00 | 100.00 | | |
No 40 | 0.425 | 179.0 | 11.1 | 11.1 | 88.9 | | |
No 200 | 0.075 | 1228.0 | 76.9 | 88 | 12 | | |
FONDO | | 163 | 10.3 | | | | |
RESULTADOS |
LIMITE LIQUIDO | NL |
LIMITE PLASTICO | NP |
INDICE PLASTICO | NP |
INDICE DE GRUPO |0 |
U.S.C. | SM-SP |
AASHTO | A-2-4 |
COMENTARIOS:HUMEDAD DE LA MUESTRA 3.61 %
FECHA: | 03 JUN | 2011 | | | | | |
CLIENTE: | | CRISTIAN C. | CUELLO | | | | |
PROYECTO: | CONSULTORIA | TECNICA | | | | |
LUGAR DEL MUESTREO: | MUNICIPIO | PONEDERA | ATLANTICO | | |
MUESTRA No: 2 | | | | | | |
PRUEBA DE GRADACION |
|
PATRONNo 1 1586 | PATRON No 2 1404 | | |
| | | |
TAMIZ | | % RETEN | % ACUM | % PASA | INF. | SUP. |
PULG. | MM | RETEN | | | | | |
| | | | | | | |
| | | | | | | |
| | | | | | | |
2 1/2" | 63 | | | | | | |
2" | 50 | | | | | | |
1 1/2" | 38.1 | | | | | | |
1" | 25 | | | | | | |
1/2" | 12.5 | | | | | | |
3/8" | 9.5 | | | | | | |
No 4 | 4.75 | | | | | | |
No 10 | 2 | 0.00 | 0.00 | 0.00 | 100.00 | | |
No 40 | 0.425 | 477.0 | 31.1 | 31.1 | 68.9 | | |
No 200 | 0.075 | 918.0 | 58.9 | 90 | 10 | | |
FONDO | | 163 | 10.3 | | | | |
RESULTADOS |
LIMITELIQUIDO | NL |
LIMITE PLASTICO | NP |
INDICE PLASTICO | NP |
INDICE DE GRUPO | 0 |
U.S.C. | SM-SP |
AASHTO | A-2-4 |
COMENTARIOS:HUMEDAD DE LA MUESTRA 2.33 %
FECHA: | 03 JUN | 2011 | | | | | |
CLIENTE: | | CRISTIAN C. | CUELLO | | | | |
PROYECTO: | CONSULTORIA | TECNICA | | | | |
LUGAR DEL MUESTREO: | MUNICIPIO | PONEDERA |ATLANTICO | | |
MUESTRA No: 3 | | | | | | |
PRUEBA DE GRADACION |
|
PATRON No 1 1586 | PATRON No 2 1404 | | |
| | | |
TAMIZ | | % RETEN | % ACUM | % PASA | INF. | SUP. |
PULG. | MM | RETEN | | | | | |
| | | | | | | |
| | | | | | | |
| | | | | | | |
2 1/2" | 63 | | | | | | |
2" | 50 | | | | | | |
1 1/2" | 38.1 | | | | | | |
1" | 25 | | | | | | |
1/2" | 12.5 | | | | | | |
3/8" | 9.5 | | | | | | |
No 4 | 4.75 | | | | | | |
No 10 | 2 | 0.00 | 0.00 | 0.00 | 100.00 | | |
No 40 | 0.425 | 545.0 | 32.1 | 32.1 | 67.9 | | |
No 200 | 0.075 | 905.0 | 56.2| 88.3 | 11.7 | | |
FONDO | | 163 | 10.3 | | | | |
RESULTADOS |
LIMITE LIQUIDO | NL |
LIMITE PLASTICO | NP |
INDICE PLASTICO | NP |
INDICE DE GRUPO | 0 |
U.S.C. | SM-SP |
AASHTO | A-2-4 |
COMENTARIOS:HUMEDAD DE LA MUESTRA 2.83 %
ESTUDIO DE DIAGNOSTICO TECNICO DEL ESTADIO DE FUTBOL DEL MUNICIPIO DE PONEDERA, ATLANTICO
ESTUDIO DE SUELOS
BARRANQUILLA,...