Ficha Lorentz
PS200 HR
Solar-operated Submersible Pump System, 4" Helical Rotor (HR) Pump Unit
Characteristics
lift up to 50 m flow rate up to 2.7 m3/h simple installation maintenance-free high reliability and life expectancy cost-efficient pumping
Components
Controller PS200 controlling of the pump system and monitoring of the operating states mounted at surface (noelectronic parts submerged) two control inputs for well probe (dry running protection), float or pressure switches, remote control etc. automatic reset 20 minutes after well probe turns pump off protected against reverse polarity, overload and high temperature speed control, max. pump speed adjustable to reduce flow rate to c. 30 % solar operation: integrated MPPT (Maximum Power PointTracking) battery operation: low voltage disconnect and restart after battery has recovered max. efficiency 92 % (motor + controller) enclosure: IP 54 (sealed, weatherproof) Motor ECDRIVE 600HR brushless DC motor no electronics inside motor water filled IP68, pressure balanced, unlimited submersion dynamic slide bearings, material: carbon/ceramic wetted material: stainless steel(AISI 316), POM, rubber, cable drinking water approved Pump End (PE) helical rotor pump (positive displacement pump) two main parts only: stator and rotor, field serviceable stator: geometry made of abrasion resistant rubber rotor: stainless steel, hard chrome plated, abrasion resistant more resistant to damage by sand than other pump types high life expectancy non-return valve dryrunning protection (optional) material: stainless steel (AISI 316), rubber self-cleaning
Applications
drinking water supply livestock watering pond management irrigation etc.
Performance
PS200 article # lift [m] max. flow rate [m3/h] max. efficiency [%] solar operation HR-04 1007-X 0 – 50 0.8 60 HR-07 1009-X 0 – 30 1.2 61 nominal voltage 24 – 48 V DC, open circuit voltagemax. 100 V DC solar generator [Wp] battery operation 80 – 300 80 – 300 nominal voltage 24 – 48 V DC 80 – 300 HR-14 1008-X 0 – 20 2.7 62
BERNT LORENTZ GmbH & Co. KG | Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 7548 - 0, Fax - 29, www.lorentz.de Errors excepted and possible alterations without prior notice.
v100520
Sun. Water. Life.
System Sizing Table: BatteryOperation
PS200 HR, 24 V DC, Battery Operation
vertical lift [m] [ft] HR-04 5 16 HR-07 HR-14 HR-04 10 33 HR-07 HR-14 HR-04 15 50 HR-07 HR-14 HR-04 20 65 HR-07 HR-14 30 40 50 100 130 165 HR-04 HR-04 HR-04 pump type peak flow rate [l/min] 5.5 7.5 17.5 5.2 7.5 16.6 4.8 7.0 15.2 4.5 6.5 12.5 4.2 3.8 3.3 [US Gal./min] 1.5 2.0 4.6 1.4 2.0 4.4 1.3 1.8 4.0 1.2 1.7 3.3 1.1 1.0 0.9 power [W] 24 37 40 29 42 5534 50 74 38 60 91 48 58 65 4.0 4.0 4.0 40 50 130 165 30 100 2.5 20 65 2.5 15 50 2.5 10 33 2.5 5 16 wire size [mm2]
PS200 HR, 48 V DC, Battery Operation
vertical lift [m] [ft] HR-04 HR-07 HR-14 HR-04 HR-07 HR-14 HR-04 HR-07 HR-14 HR-04 HR-07 HR-04 HR-07 HR-04 HR-07 HR-04 pump type peak flow rate [l/min] 11.0 17.0 38.4 10.3 16.5 36.1 10.1 15.8 35.0 9.8 15.5 9.3 14.2 8.7 13.5 7.8 [US Gal./min]2.9 4.5 10.1 2.7 4.4 9.5 2.7 4.2 9.2 2.6 4.1 2.5 3.8 2.3 3.6 2.1 power [W] 55 90 130 70 100 165 80 115 195 90 135 105 160 125 190 140 2.5 2.5 2.5 2.5 wire size [mm2]
4.0
4.0 4.0
For Battery and Solar Direct Systems
Lift Limits These systems are selected for optimum performance. To allow unexpected drawdown, each system can handle an additional 15 % lift. Higher Lift? Higher Flow Rate?Choose PS600/1200 for higher lift, higher flow rate applications and lower cable cost. Wire Sizes Cable Layout is calculated to stay within 4 % power loss. Variations of Length Longer: for each 50 % increase, the next larger wire size is required Shorter: for each 33 % decrease, the next smaller wire size is required Array To Controller: if shorter than 6 m/20 ft: 4 mm2 / #10 min. Controller To...