DESCRIPTION
The 13 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be custom-matched with one of UPG’s complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heatersare available, if required. Add-On coils are available for use
with upflow, downflow, or horizontal furnaces and air handlers.

WARRANTY

TECHNICAL GUIDE

Single Phase Units:
5-year limited parts warranty.
5-year limited compressor warranty.

SPLIT-SYSTEM
AIR CONDITIONERS

FEATURES

13 SEER – R-22
MODELS:
YCJD18 THRU 60
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)

LISTED

ISO 9001Certified Quality
Management System

Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com

• QUALITY CONDENSER COILS - The coil is constructed
of aluminum microchannel tubing and enhanced aluminum
fins for increased efficiency and corrosion protection.
• PROTECTED COMPRESSOR - The compressor is internallyprotected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a betterpaint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connections. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet ofinterconnecting piping. The small base dimension means less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top paneleffectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant connections, and a single panel covering the electrical controls make for easyservicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.

Additional rating information canbe found at
www.ahridirectory.org

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

401493-YTG-A-0408

Physical and Electrical Data
YCJD18
S21S2(H)

MODEL

YCJD24
S21S2(H)

YCJD30
S21S2(H)

YCJD36
S21S2(H)

YCJD42
S21S2(H)

YCJD48
S21S2(H)

YCJD60
S21S2

208-230V, 1φ, 60Hz

Unit Supply Voltage
Normal Voltage Range

1

187 to 252

MinimumCircuit Ampacity
Max. Overcurrent Device Amps

9.5
2

Min. Overcurrent Device Amps 3
Compressor Type

11.3

14.0

18.2

19.9

22.7

33.5

15

15

20

30

30

35

50

15

15

15

20

20

25

35
Scroll

Rotary

Recip

Recip

Recip

Recip

7.2

8.4

10.6

13.4

14.7

17.0

25.6

Locked Rotor

40.0

47.0

61.0

78.0...