Historia De La Contabilidad
Calibre
(AWG/MCM)
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000
Sección
Standard
mm2
2.5
4.00
6.00
10.00
16.00
25.00
35.00
42.00
50.00
70.00
85.00
95.00
120.00
150.00
175.00
185.00
240.00
300.00
400.00
500.00
(A)
Ducto
15
20
30
45
65
85
115
125
150
175
200
230
255
285
310335
380
420
490
580
CONSUMO DE COMBUSTIBLE
DIESEL
=
0.080 X KW
= Gal. / Hora
CONVERSION DE KVA A KW (KVA x 0.8 = KW)
(KW / 0.8 = KVA)
ESPECIFICACIONES CONDUCTORES THW – 90 mm2
Calibre
(A)
(A)
Calibre
(A)
(A)
(mm2)
Aire Ducto
(AWG/MCM) Aire Ducto
37
27
35
25
2.5
14
45
34
40
30
4
12
61
44
56
40
6
10
88
62
80
56
10
8
124
85
107
75
16
6
158107
141
96
25
4
197
135
192
130
35
2
245
160
220
147
50
1
307
203
260
170
70
1/0
375
242
300
197
95
2/0
437
279
350
226
120
3/0
501
318
406
260
150
4/0
586
361
457
290
185
250
654
406
505
321
240
300
767
462
569
350
300
350
908
541
615
378
400
400
1037
603
699
429
500
500
ESPECIFICACIONES CONDUCTORES TW – 80 mm2
Calibre(A)
(A)
Calibre
(A)
(A)
(mm2)
Aire Ducto
(AWG/MCM) Aire Ducto
30
24
28
22
2.5
14
35
31
33
28
4
12
50
39
44
33
6
10
74
51
66
44
10
8
99
68
88
61
16
6
132
88
116
77
25
4
165
110
154
105
35
2
204
138
182
121
50
1
253
165
215
138
70
1/0
303
198
248
160
95
2/0
352
231
286
182
120
3/0
413
264
330
215
150
4/0
473
303
374237
185
250
528
352
413
264
240
300
633
391
462
286
300
350
737
451
501
308
400
400
858
506
567
352
500
500
ESPECIFICACIONES CABLES NYY TRIPLE
Calibre
(A)
(A)
(A)
(mm2)
Aire Ducto Enterrado
54
58
72
3x1x6
74
77
95
3x1x10
100
102
127
3x1x16
131
132
163
3x1x25
161
157
195
3x1x35
196
186
230
3x1x50
250
222
282
3x1x70
306
256
336
3x1x95301
382
3x1x120 356
408
338
428
3x1x150
367
483
3x1x185 470
426
561
3x1x240 562
480
632
3x1x300 646
555
730
3x1x400 790
567
823
3x1x500 895
ESPECIFICACIONES CORDONES VULCANIZADO NLT
Calibre (A)
Calibre
(A)
(mm2)
(AWG/MCM)
7
2x0.75 10
2x20
12
10
2x1.0
2x18
20
15
2x2.5
2x16
20
2x14
7
3x18
10
3x16
15
3x14
10
4x16
15
4x14
ESPECIFICACIONES CORDONESVULCANIZADO NMT
Calibre
(A)
Calibre
(A)
(mm2)
(AWG/MCM)
10
18
2x0.75
2x14
12
25
2x1.0
2x12
15
30
2x1.5
2x10
20
15
2X2.5
3x14
26
20
2X4
3x12
7
25
3X0.75
3x10
9
20
3X1.0
4X12
12
25
3X1.3
4x10
17
3X2.5
23
3X4
ESPECIFICACIONES CORDONES VULCANIZADO NPT
Calibre (A)
Calibre
(A)
(mm2)
(AWG/MCM)
33
25
2x6
2x12
45
30
2x10
2x10
60
40
2x16
2x8
8055
2X25
2x6
95
20
2X35
3x12
28
25
3X6
3x10
40
35
3X10
3X8
50
45
3X16
3X6
70
60
3X25
3X4
80
80
3X35
3X2
100
3X1/0
116
3X2/0
132
3X3/0
156
3X4/0
14
4X14
18
4X12
21
4X10
30
4X8
40
4X6
55
4X4
75
4X2
90
4X1/0
102
4X2/0
116
4X3/0
137
4X4/0
ESPECIFICACIONES CABLES PARA SOLDAR WS
Calibre (A)
(AWG)
100
8
145
6
190
4
254
2
300
1
3541/0
409
2/0
472
3/0
545
4/0
FORMULAS PARA CORRIENTE HP, KW Y KVA
DC
DATO
1Ø
3Ø
I
=
HP x 746
E x %eff.
HP x 746
E x FP x %eff
HP x 746
1.73 x E x FP x %eff
I
=
KW x 1000
E
KW x 1000
E x FP
Kw x 1000
1.73 x E x FP
I
=
KVA x 1000
E
KVA x 1000
1.73 x E
KW =
IxE
1000
I x E x FP
1000
IxE
1000
KVA=
HP =
I x E x %eff
746I x E x FP x 1.73
1000
I x E x 1.73
000
I x E x FP x %eff
746
I x E x 1.73 x FP x %eff
746
CONSUMO DE COMBUSTIBLE
DIESEL
GAS
=
=
0.080 X KW
15.000 X KW
= Gal. / Hora
= BTU/ hora
CONVERSION DE KVA A KW (KVA x 0.8 = KW)
(KW / 0.8) = KVA)
INSTALACIONES EN TUBO DE CABLES TW Y THW
Calibre
AWG
MCM
NUMERO DE CONDUCTORES QUE PUEDEN INSTALARSE EN
TUBO
1/2"...
Regístrate para leer el documento completo.