VTP & VPC

Vertical Turbine Wet Pit and Double Casing Pumps MAINTENANCE CHECKLIST
Read User Instructions before installing, operating or maintaining this pump. Copies available from Flowserve pump representative.
Operating Limits Pumped Liquid Temperature Limits* Maximum Ambient Temperature* Maximum Pump Speed 5°C (40°F) to +80°C (176°F) Up to +40°C (104°F) Refer to the Nameplate

* Subjectto written agreement from Flowserve. Special designs and materials may be available for pumps operating above and below these specified limits. Contact Flowserve for upgrade options available for your specific application.

Impeller Clearance Settings Flowserve recommends the following impeller settings based on the pump sizes. If the Pump Size Is: Size 6 thru size 12 Size 14 and above Settingfor Enclosed Impellers 3~4 mm (0.13~0.15 in) 6~7 mm (0.25~0.27 in) Setting for Semi-Open Impellers 0.25 mm to 0.38 mm (0.010 in to 0.015 in) 0.63 mm to 0.76 mm (0.025 in to 0.030 in)

Note: Shafts elongate due to the hydraulic thrust of the pump and the impellers must be compensated for this elongation. Shaft elongation varies for each model depending upon the size, shaft length, shaft diameter,impeller weight, number of stages. Please see the documentation supplied along with the pump for exact impeller setting value matched for the specific pump that you have purchased

Shaft / Bearing Clearance
Shaft Size mm (in) 25.40 (1.000) 31.75 (1.250) 38.10 (1.500) 42.86 (1.690) 49.21 (1.940) 55.56 (2.190) 61.91 (2.440) 68.26 (2.690) 74.61 (2.940) 82.55 (3.250) 88.90 (3.500) 95.25 (3.750)101.60 (4.000) 114.30 (4.500) 127.00 (5.000) Shaft Diameter/Tolerance (Min Dia - Max Dia) mm (in) 25.35 (0.998) 31.70 (1.248) 38.05 (1.498) 42.81 (1.685) 49.16 (1.935) 55.51 (2.185) 61.86 (2.435) 68.21 (2.685) 74.56 (2.935) 82.47 (3.247) 88.82 (3.497) 95.17 (3.747) 101.58 (3.997) 114.22 (4.497) 126.92 (4.997) 25.40 (1.000) 31.75 (1.250) 38.10 (1.500) 42.86 (1.687) 49.21 (1.937) 55.56 (2.187) 61.91(2.437) 68.26 (2.687) 74.61 (2.937) 82.55 (3.250) 88.90 (3.500) 95.25 (3.750) Bearing Clearance (Max/Min) mm (in) 0.28/0.13 (0.011/0.005) 0.35/0.15 (0.012/0.006) 0.33/0.18 (0.013/0.007) 0.36/0.18 (0.014/0.007) 0.38/0.23 (0.015/0.008) 0.41/0.23 (0.016/0.009) 0.41/0.23 (0.016/0.009) 0.43/0.23 (0.017/0.009) 0.43/0.23 (0.017/0.009) 0.46/0.25 (0.018/0.010) 0.48/0.28 (0.019/0.011) 0.53/0.35 (0.021/0.012)101.60 (4.000) 0.56/0.33 (0.022/0.013) 114.30 (4.500) 0.58/0.35 (0.023/0.014) 127.00 (5.000) 0.61/0.38 (0.024/0.015)
Latin America Flowserve Corporation Boulevard del Cafetal Edificio Ninina, Local 7 El Cafetal - Caracas Venezuela 1061 Telephone: 58 212 985 3092 Telefax: 58 212 985 1007 Asia Pacific Flowserve Pte. Ltd. 10 Tuas Loop Singapore 637345 Telephone: 65 6771 0600 Telefax: 65 67794607

USA and Canada Flowserve Corporation 5215 North O’Connor Blvd. Suite 2300 Irving, Texas 75039-5421 USA Telephone: 1 937 890 5839

Europe, Middle East, Africa Flowserve Corporation Gebouw Hagepoint Westbroek 39-51 4822 ZX Breda Netherlands Telephone: 31 76 502 8920

For sales product information, go to www.flowserve.com
(FPD-1363) (E) December 2009 © Flowserve Corporation

Bolt TorqueValues for Class 2 Lubricated Treads
Material Group Thread Data A 316 SS B ASTM B164 UNS NO4400 276 (40000) 5 (4) 8 (6) 14 (10) 20 (15) 31 (23) 45 (33) 60 (44) 101 (75) 163 (120) 244 (180) 352 (260) 366 (270) 488 (360) 502 (370) 570 (420) 610 (450) 746 (550) 800 (590) 963 (710) 1031 (760) 1180 (870) 1302 (960) C Hastelloy C276 345 (50000) 5 (4) 11 (8) 16 (12) 25 (19) 39 (29) 75 (41) 54 (73) 127(94) 203 (150) 312 (230) 448 (330) 461 (340) 610 (450) 637 (470) 719 (530) 760 (560) 936 (690) 990 (730) 1207 (890) 1302 (960) D ASTM A449 Grade 5 441 (60000) 7 (5) 14 (10) 20 (15) 31 (23) 47 (35) 66 (49) 88 (65) 149 (110) 258 (190) 366 (270) 529 (390) 556 (410) 746 (550) 760 (560) 855 (630) 922 (680) 1126 (830) 1194 (880) E ASTM A193 Grade B7M 552 (80000) 9 (7) 17 (13) 27 (20) 42 (31) 62 (46) 89...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • Ing. industrial
  • Ing. Industrial
  • Ing. Industrial
  • Ing Industrial
  • ING. INDUSTRIAL
  • Ing Industrial
  • Ing industrial
  • ing. industrial

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS