Ingeniero Eléctrico
Safety precautions Introduction
I II 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Contents
Industrial Inverter
For 3-phase induction motors
Read first
Connection
Operations
Instruction Manual
TOSVERT
TM
Basic VF-S11 operations Basic parameters Extended parameters Applied operation Monitoring the operation status Measures to satisfy the standards
VF-S111-phase 240V class 3-phase 240V class 3-phase 500V class 3-phase 600V class
0.2 0.4 0.4 0.75
2.2kW 15kW 15kW 15kW
Peripheral devices Table of parameters and data Specifications Before making a service call
NOTICE 1.Make sure that this instruction manual is delivered to the end user of the inverter unit. 2.Read this manual before installing or operating the inverter unit, and store it in asafe place for reference.
Inspection and maintenance Warranty Disposal of the inverter
2004 Ver. 108/109
■Errata sheet
This Errata sheet is applied since the software version V116/117. 1. Page 54, 57, 58, 60, 63 The following new functions are added. Title f209 f319 Function Analog input filter Regenerative over-excitation upper limit Canceling mode of stall prevention PWM carrierfrequency at low speed Limiting function of starting current Adjustment range 0 - 5 (small - big) 100 - 160 0: Setting acceleration time 1: Shortest acceleration time 1.0 - 11.0 (kHz) 0: Disabled 1: Enabled 0: Deselect 1: Select (When the input power becomes off, the drive memorizes the motor and the drive thermal state. When the power comes back, the drive starts at the memorized thermal state.) 0.00- 650.00 stall 0.0 : Deselect 0.1(Hz) - fh Default setting 4 140
f396
0
f482 f497
3.0 1
f632
Thermal memory selection
0 (AN, WP) 1 (WN)
f913 f914
d axis inductance (for PM drive) Cancel frequency of prevention(for PM drive)
0.00 0.0
2. Page 58 The adjustment range of following parameter is changed. Title f495 Function Maximum voltage adjustment coefficientAdjustment range 90 - 120 (%) Default setting 104
3. Page 51 The default setting of following functions are changed. Title fm Function FM terminal meter adjustment Adjustment range Default setting This value is adjusted for the optional frequency meter QS-60T.
1
4. Page 67 The following new functions are added. Function No. 66 67 68 69 70 71 72 73 74 75 Code ST+F+SS1 ST+R+SS1 ST+F+SS2ST+R+SS2 ST+F+SS3 ST+R+SS3 ST+F+SS4 ST+R+SS4 ST+F+JOG ST+R+JOG Function Combination of standby, forward run and preset-speed command 1 Combination of standby, reverse run and preset-speed command 1 Combination of standby, forward run and preset speed command 2 Combination of standby, reverse run and preset-speed command 2 Combination of standby, forward run and preset speed command 3 Combination ofstandby, reverse run and preset-speed command 3 Combination of standby, forward run and preset speed command 4 Combination of standby, reverse run and preset-speed command 4 Combination of standby, forward run and jog run Combination of standby, reverse run and jog run Action ON: Simultaneous input from ST, F and SS1 ON: Simultaneous input from ST, R and SS1 ON: Simultaneous input from ST, F and SS2ON: Simultaneous input from ST, R and SS2 ON: Simultaneous input from ST, F and SS3 ON: Simultaneous input from ST, R and SS3 ON: Simultaneous input from ST, F and SS4 ON: Simultaneous input from ST, R and SS4 ON: Simultaneous input from ST, F and JOG ON: Simultaneous input from ST, R and JOG
5. Page 52 (Related model is only WP model) “pt” default setting was changed. (pt =2 →pt =0) In caseyou use pt =2 (Automatic torque boost control), Please change “pt” from “0” to “2”. Title Function Adjustment range 0: V/F constant 1: Variable torque 2: Automatic torque boost control 3: Vector control 4: Energy-saving 5: Dynamic energysaving (for fans and pumps) 6: PM motor control Default setting
pt
V/F control mode selection
0
2
6. The specification of “f307 : Supply voltage...
Regístrate para leer el documento completo.