Instacion De Alarmas

Páginas: 31 (7519 palabras) Publicado: 27 de febrero de 2013
ENGLISH
The detector provides an analysis of environmental conditions through the entire movement speed frequency spectrum, allowing focus on intruders and eliminating environmental factors of false alarms. The spectrum analysis is embedded in the VLSI based electronics of the detector assuring high reliability and trouble free operation. As the LC-104 (Form A) and LC-124 (Form C) is a combinedtechnology (PIR & microwave) alarm signal relay activation occurs only when signals from both sensors (PIR & MW) are present at the same time. The effective detection range is the range of which the patterns (PIR & MW) are intersected. The GAIN potentiometer adjustment changes the MW signal intensity so that the effective pattern will be scaled. This Installation Manual shall be used inconjunction with the Installation Manual of the ALARM Control Panel. TYPICAL INSTALLATION Select mounting location Choose a location most likely to intercept an intruder. (Our recommendation is a corner installation). See detection pattern (Fig.3). The quad-element high quality sensor detects motion crossing the beam; it is slightly less sensitive detecting motion toward the detector. Avoid The FollowingLocations: * Facing direct sunlight. * Facing areas that may change temperature rapidly. * Areas where there are air ducts or substantial airflows. The LC-104-PIMW / LC-124-PIMW perform better when provided with a constant and stable environment. This detector shall be installed and used within an environment that provides the pollution degree max 2 and overvoltages category II, NON HAZARDOUSLOCATIONS, indoor only. The detector is designed to be installed by service persons only. MOUNTING THE DETECTOR 1. Remove the front cover by unscrewing the holding screw (Fig. 2-11) and gently raise the front cover. (Fig. 2 -5) 2. Remove the PC board by unscrewing the holding screw located on the board.(Fig. 2 - 9) 3. Break out the desired holes for proper installation (Fig. 1 – 2) for flat mount orFig. 1-3 for corner mount) Use 4 screws type 3x30mm. 4. The circular and rectangular indentations at the bottom base (Fig. 11, Fig. 1-4) are the knockout holes for wire entry. 5. Mount the detector base to the wall or corner. 6. For optional bracket installation open hole Fig. 1-6 for the bracket screw and install Bracket wall adapter (Fig. 2-1&3) or Bracket ceiling adapter (Fig. 2-2&3) 7. Reinstallthe PC board by fully tightening the holding screw. 8. Connect wire to terminal block.(Fig. 4) 9. Replace the cover by inserting it back in the appropriate closing pins and screw in the holding screw. If back tamper is assembled (Fig.1-6) there is no bracket option and the detector must be installed in flat mounting only DETECTOR INSTALLATION Terminal Block Connections (See Fig. 4) Terminals 1 & 2- Marked “T2, T1” (TAMPER) Connect these terminals to a 24-hour normally closed protective zone in the control unit. If the front cover of the detector is opened, an immediate alarm signal will be sent to the control unit. Terminal 3 Marked "NC" - This is the NC (Normally Closed) output of ALARM relay. (This contact is functional on LC-104-PIMW and LC-124PIMW) Terminal 4 Marked "C" - This is theCOMMON output of ALARM relay (This contact is functional on LC-104-PIMW and LC-124-PIMW). Terminal 5 Marked "NO" - This is the NO (Normally Open) of ALARM relay (This contact is functional on LC-124-PIMW only). Terminal 6 – Marked "-" (GND) Connect to the negative Voltage output or ground of the control panel. Terminal 7 - Marked "+" (+12V) Connect to a positive Voltage output of 9.6-16VDC source.Use only a listed power limited source. Note: The detector shall be provided with minimum of 4 hours of standby power from either a listed compatible control unit or power supply. SETTING - UP THE DETECTOR (Dipswitch Fig.5-2) LED ENABLE / DISABLE Switch 1 of dipswitch marked "LED" - LED's Enable/Disable Position Up “ON” – LED's ENABLE The 3 LED's will be activating Red for ALARM, Green for PIR...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • Alarma
  • Alarma laser
  • alarma
  • alarma
  • Alarma Laser
  • Alarma
  • Alarma
  • Alarma

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS