Series 02 Push-to-Reset

Superior Short Circuit Protection
MP Series 02 includes Models 252, 600, and 601 Push-to-Reset circuit breakers. Together, they provide powerful security against hazardous fault currents. A distinctive characteristic of this design is its double-contact break, supported by the unique saddle-shaped thermal sensing element. This configuration allows some models in thisfamily to withstand short circuit conditions as high as 5,000A and continue to function.

89 t UL4 Rese toion Pushrotect allest Sm ircuit P ’s hC World Branc gnized Reco

High Capacity in a Small Package
Model 252 is UL489 recognized for branch circuit protection. As such, it is one of the smallest units available that is capable of withstanding a 5,000A short circuit . Such outstandingperformance allows you to specify Model 252 in tight enclosures where high fault current protection is vital, thereby eliminating the necessity for other protective devices in series. Models 600 and 601 are UL recognized per UL1077 as supplementary circuit protection devices, c a pa b l e of opening circuit voltages of up to 277VAC and 32VDC.

Mechanical Products Company phone 517 782 0391 fax 517 7886773 www.mechprod.com mpsales2@mechprod.com

S02-1

Series 02

Push-to-Reset

Series 02 Physical Configuration
Unique Double-Contact Break Mechanism

Plunger Assembly & Actuator Mounting Sleeve

Double Contact Mechanism Saddle-Shaped Sensing Element

Return Spring Terminal

The internal workings of all models in Series 02 are based on a double-contact break mechanism. When aSeries 02 breaker responds to an overcurrent, the saddle-shaped bimetal disconnects the circuit in two locations. This provides higher resistance to arcing than the same spacing of single-contact separations, and thus, superior short circuit protection. This original design has qualified Model 252 to a UL489 rating for Branch Circuit Protection, and allows models 600 and 601 to be rated at 277VAC and32VDC - a superior voltage rating for their package size. (Consult specification sheet for details.)

For applications assistance call 517-782-0391 FAX 517-788-6773

S02-2

5.0 – 30.0 Amps

Series 02 Physical Configuration (continued)
Physical Attributes: Models 252-600
.687

1.375

.187

.19

.33

1.43

1.88

.687

.625 1.375

Models 252 and 600 offer single-pole,push-to-reset circuit protection. Standard terminals are 0.250” quick-connect-type. Standard through-the-hole mounting, is a threaded 3/8”-27 bushing with a D-shaped flat for anti-rotation requirements.

Note: All dimensions are in inches.

Mechanical Products Company phone 517 782 0391 fax 517 788 6773 www.mechprod.com mpsales2@mechprod.com

S02-3

Series 02 Push-to-Reset

Series 02Physical Configuration (continued)
Mounting Considerations If the actuator button is imprinted with the amp rating, the flat on the panel cutout should be to the left of the actuator in vertical orientation. If no amp stamp is specified, the flat can be oriented parallel or perpendicular to the case seam.

Mounting Hardware

Standard Terminals on Model 601

Model 601, rated at 30A, comes withstandard #10-32 screw terminals.

Note: All dimensions are in inches.

For applications assistance call 517-782-0391 FAX 517-788-6773 S02-4

5.0 – 30.0 Amps

Series 02 Specifications
Standard Amperage Ratings Model 252 is offered in ratings of 10A, 15A & 20A. Model 600 is offered in ratings of 5A, 7A, 10A, 15A, and 20A. Model 601 is offered in a 30A rating. Voltage Ratings Model 252 israted at 120VAC Model 600 is rated at 277VAC/32VDC Model 601 is rated at 277VAC Interrupt Capacity (UL489 and UL1077) Model 252 short circuit interrupt capacity of 5,000A/120VAC per UL489 Model 600 short circuit interrupt capacity of 5,000A/277VAC per UL1077 1,000A/120VAC per UL1077 Model 601 short circuit interrupt capacity of 5,000A/277VAC per UL1077 Inrush Capacity Series 02 Models will not...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • Licenciatura
  • Licenciatura
  • Licenciatura
  • Licenciatura
  • Licenciatura
  • Licenciatura
  • Licenciatura
  • Licenciatura

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS