Manula Timer H3Y
H3Y
CSM_H3Y_DS_E_3_2
Miniature Timer Compatible with the MY Relay
• Semi-multi power supply voltage. • Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver can also be used for time setting. • Pin configuration compatible with MY Power Relay. • LED indication for power and output statuses. • Conforms to EMC standards. •Conforms to EN61812-1 and approved by UL and CSA.
Ordering Information
Operation/ resetting system Time-limit contact Time ranges Supply voltage Mounting Surface/DIN-track mounting (with socket) 0.04 s to 3 h 24, 100 to 120, 200 to 230 VAC H3Y-2 (50/60 Hz); 12, 24, 48, 125, 100 to H3Y-4 (See note 3.) 110 VDC Surface mounting (with PCB terminals) H3Y-2-0 H3Y-4-0 (See note 3.)
Time-limitoperation/ DPDT (for power self-resetting switching) 4PDT
Note: 1. Specify both the model number, supply voltage, and rated time when ordering.
Ex. H3Y-2 100 to 120 VAC 0.5 s Rated time Supply voltage 2. Sockets and Hold-down Clips are not included with the H3Y. They must be ordered separately. 3. Use the H3Y-4 or H3Y-4-0 Series when switching micro loads.
■ Accessories (Order Separately)Adapter, Mounting Plate, Clip
Name/specification Flush mounting adapter Mounting Plate for Socket Clip For 1 Socket For 18 Sockets For PYF@A For PY@ and PYF@M Y92F-78 PYP-1 PYP-18 Y92H-3 Y92H-4 DPDT H3Y-2 8-pin H3YN-2@ Model
Socket
Timer Contact Model Pin Square Sockets Connection Terminal DIN track mounting Model PYF08A
DIN track Front mounting PYF08A-E Connecting (Fingersafe tyape) DIN trackmounting Back Solder Connecting terminal DIN track mounting PYF08F PY08 PYF14A
Note: For details, refer to Safety Precautions.
4PDT
Front DIN track Connecting mounting H3Y-4 14-pin PYF14A-E H3YN-4@ (Fingersafe tyape) Back Solder Connecting terminal PY14
Note: 1. Cannot be used with the H3Y-@-0 (PCB terminals). 2. The PYF@@A-E has a finger-protection structure. Round crimp terminalscannot be used. Use forked crimp terminals. 3. For details, refer to Socket and DIN Track Products.
1
H3Y
Specifications
■ Time Ranges
Rated time 0.5 s 1s 5s 10 s 30 s 60 s 120 s Time setting range 0.04 to 0.5 s 0.1 to 1 s 0.2 to 5 s 0.5 to 10 s 1.0 to 30 s 2.0 to 60 s 5.0 to 120 s 3 min 5 min 10 min 30 min 60 min 3h --Rated time Time setting range 0.1 to 3 min 0.2 to 5 min 0.5 to 10 min 1to 30 min 2 to 60 min 0.1 to 3 h ---
■ Ratings
Item Rated supply voltage (See note 6.) Operating voltage range Reset voltage Power consumption H3Y-2(-0)/H3Y-4(-0) 24, 100 to 120 (50/60 Hz), 200 to 230 VAC (50/60 Hz) (See note 1.), 12, 24, 48, 125, 100 to 110 VDC (See notes 2 and 3.) All rated voltages except 12 VDC: 85% to 110% of rated supply voltage 12 VDC: 90% to 110% of rated supplyvoltage (See note 4.) 10% min. of rated supply voltage (See note 5.) 100 to 120 VAC: 200 to 230 VAC: 24 VAC: 12 VDC: 24 VDC: 48 VDC: 100 to 110 VDC: 125 VDC: Control outputs Note: 1. 2. 3. 4. Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz Relay ON:Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz Relay ON: Approx. 1.1 W at 12 VDC Relay OFF: Approx. 0.1 W at 12 VDC Relay ON: Approx. 1.1 W at 24 VDC Relay OFF: Approx. 0.1 W at 24 VDC Relay ON: Approx. 1.2 W at 48 VDC Relay OFF: Approx. 0.3 W at 48 VDC Relay ON: Approx. 1.6 W at 110 VDC Relay OFF: Approx. 0.4 W at 110 VDC Relay ON: Approx. 1.6 W at 125VDC Relay OFF: Approx. 0.4 W at 125 VDC
H3Y-2(-0): 5 A at 250 VAC, resistive load (cosφ = 1) H3Y-4(-0): 3 A at 250 VAC, resistive load (cosφ = 1)
Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Times for details. With DC ratings, single-phase full-wave rectified power sources may be used. Only the H3Y-2 and H3Y-2-0 Series include 2-VDC...