·POWER SUPPLY:DC12V 1A.
·OPERATION CURRENT 900mA, HOLDING CURRENT 360mA . ·FAILSAFE TYPE (POWER LOCK) · DOOR SENSOR:N.C.(SL100A),N.C. &N.O.(SL100B) · OPERATION DELAY TIME:0 SEC. 2.5SEC. 5SEC. 9SEC. · BUILTIN DELAYED EGRESS CONTROL POINT · FACE PLATE:200mm(L)x32mm(W)x40mm(D) · STRIKE PLATE:90mm(L)x26mm(W)x2mm(D) SL100A (5 PIN ) BROWN :GND RED : + DC12V ORANGE : PUSH BUTTON YELLOW : DOOR POSITION SENSOR(N.C.) GREEN : DOOR POSITION SENSOR(COM.) SL100B (6 PIN ) BROWN : GND RED : + DC12V ORANGE : PUSH BUTTON YELLOW : DOOR POSITIONSENSOR(N.C.) GREEN : DOOR POSITION SENSOR(COM.) BLUE : DOOR POSITION SENSOR(N.O.)
READER PUSH BUTTON
N.C. N.O.
COM
SL100
ORANGE BROWN RED
+DC12V
AP10
DC 12V 1A
0 SEC.
5 SEC. 9SEC.
Setting door lock delay timer :
2.5 SEC.
※Please switch on the appliance again to validate any adjustment of DIP switch value
Page 1
Accessories:
X 1 Lock body
X 1 Strikeplate
X 2 Shims(small) For strike plate
X 2 Shims (Large) for Lock body 5PIN Connector
SCREWS:
X 8 Small wood screws for strike plate( 4 x 8 mm) X 4 Large metal screws for lock body andshims( 5 x 8 mm) X4 Small metal screws for strike plate and shims( 4 x 26 mm) X 2 Large wood screws for lock body( 5 x 15 mm)
Lock body templates Strike plate template
Faceplate
Current andTemperature Chart:
Time (sec.)
~ ~
900 800 700 600 Current 500 (mA) 400 300 200 100
Start Standby Door Close Delay Time Setting
0 70 65 60 55 Temperature 50 (℃) 45 40 35 30 25 1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 Time (sec.)
~ ~ 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Time (min.)
Supply power & doorclose Page 2
Installation:
Instruction: Diagram 1: Dimensions Diagram 2: For double door mounting Diagram 3: For single door mounting Diagram 4: For vertical mounting ImportantFor vertical...