Nivel Peroxido
micropilot M FMR 245 HART/4...20 mA Level-Radar
Operating Instructions
HART
R
FIELD COMMUNICATION PROTOCOL
Micropilot M FMR 245 with HART/4...20 mA
Brief operating instructions
KA 159F/00/a2/05.02 52006292
000 measured value
+
Micropilot M - Briefoperating instructions
+ or +
E
+
Contrast:
E E E
Group selection 00 basic setup
+
008 dist./ meas value
002 tank shape - dome ceiling - horizontal cyl. - bypass …
003 medium cond.
004 process cond.
005 empty calibr.
006 full calibr.
007 pipe diameter
008 dist./ meas value
051 check distance
052 range of mapping confirm suggestion or specify range
053 startmapping
01 safety settings 04 linearisation 05 extended calibr. 06 output (HART, FF) profibus param.(PA) 09 display 0E envelope curve
input E input F - unknown - standard only for (see sketch) (see sketch) bypass + - DC: 10 …
D and L are - ok displayed - too small (see sketch) - too big - unknown - manual
threaded connection: reference point of measurement
092 language 0E1 plotsettings - envel. curve - incl. FAC - incl. cust. map
… …
D
0E2 recording curve - single curve - cyclic flange: reference point of measurement
… …
E F L
-
0A diagnostics 0C system parameter
0A0 present error
0A1 previous error
0A4 unlock parameter = 100: unlocked ≠ 100: locked
… …
} HART = 2457: unlocked PA, FF ≠ 2457: locked }
52006292
L00-FMR2xxxx-19-00-00-en-039!
Note! This operating manual explains the installation and initial start-up for the level transmitter. All functions that are required for a typical measuring task are taken into account here. In addition, the Micropilot M provides many other functions that are not included in this operating manual, such as optimising the measuring point and converting the measured values. An overview of alldevice functions can be found on Page 82. The operating manual BA 221F/00/en "Description of the instrument functions for Micropilot M" provides an extensive description of all device functions, which can be found on the enclosed CD-ROM.
2
Endress + Hauser
Micropilot M FMR 245 with HART/4...20 mA
Endress + Hauser
Table of contents
1
1.1 1.2 1.3 1.4
Safety instructions . . . . .. . . . . . . . . 4
Designated use . . . . . . . . . . . . . . . . . . . . . . . . Installation, commissioning and operation . . . Operational safety . . . . . . . . . . . . . . . . . . . . . . Notes on safety conventions and symbols . . . 4 4 4 5
9.7 9.8 9.9
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Software history . . . . . . . . . . . . . . . . . . . . . . .77 Contact addresses of Endress+Hauser . . . . . 77
10
Technical data . . . . . . . . . . . . . . . . . 78
10.1 Additional technical data . . . . . . . . . . . . . . . . 78
2
2.1 2.2 2.3 2.4
Identification . . . . . . . . . . . . . . . . . . . 6
Device designation . . . . . . . . . . . . . . . . . . . . . Scope of delivery . . . . . . . . . . . . . . . . . . . . . . .Certificates and approvals . . . . . . . . . . . . . . . . Registered trademarks . . . . . . . . . . . . . . . . . . 6 8 8 8
11
Appendix . . . . . . . . . . . . . . . . . . . . . . 82
3
3.1 3.2 3.3 3.4 3.5
Mounting . . . . . . . . . . . . . . . . . . . . . . 9
Quick installation guide . . . . . . . . . . . . . . . . . . 9 Incoming acceptance, transport, storage . . . 10 Installation conditions. . . . . . . . . . . . . . . . . . 11 Installation instructions . . . . . . . . . . . . . . . . . 17 Post-installation check . . . . . . . . . . . . . . . . . . 22
11.1 Operating menu HART (display modul), ToF Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 11.2 Operating matrix HART / Commuwin II . . . . . . 84 11.3 Description of functions . . . . . . . . . . . . . . . ....
Regístrate para leer el documento completo.