ARTÍCULO PRODUCTO DE LA INVESTIGACIÓN
Calidad físico-química y microbiológica del agua del
municipio de Bojacá, Cundinamarca
Sandra Mónica Estupiñán Torres¹, Sara Lilia Avila de Navia¹
¹ Docentes. Programa de Bacteriología y Laboratorio Clínico, Facultad de Ciencias de laSalud, Universidad
Colegio Mayor de Cundinamarca, Bogotá, Colombia.
Correspondencia: sestupinan@unicolmayor.edu.co
Recibido: 11-08-10 / Aceptado: 22-11-10
Resumen
Este estudio determinó si el agua para consumo humano del área urbana en el municipio de Bojacá
Cundinamarca, cumplía con los parámetros físicos, químicos y microbiológicos establecidos en la Resolución
2115 de 2007. Para ello, serealizaron dos muestreos de diferentes puntos de la red de distribución, fuentes
naturales y tanques de almacenamiento domiciliario. Se emplearon métodos fotométricos, electrométricos
y volumétricos en los respectivos análisis físicos y químicos, para los parámetros microbiológicos se
empleó la técnica de filtración por membrana. Los resultados obtenidos evidenciaron que la mayoría de
las muestras nocumplió con en el valor mínimo permisible de cloro residual libre, por lo tanto, según el
indice de riesgo de la calidad del agua para consumo humano (IRCA), son clasificadas como no aptas para
consumo humano. Sin embargo, los demás parámetros analizados incluso los microbiológicos cumplieron
los parámetros estipulados en la Resolución 2115 de 2007. La calidad del agua debe mantenerse en todo
elsistema de distribución, por lo tanto, además de llevar a cabo los procesos de potabilización, el prestador
del servicio debe llevar un estricto control de los factores que puedan influir en la calidad del agua.
Palabras clave: Calidad del agua, agua potable, coliformes, Escherichia coli, IRCA, Red de distribución.
Abstract
Physicochemical and microbiological water quality of Bojacá Township,Cundinamarca
This study determined whether the drinking water in urban areas in the municipality of Cundinamarca
Bojacá, met the physical, chemical and microbiological criteria established in Resolution 2115 of 2007.
To this end, there were two samples from different parts of the distribution system, natural sources and
storage tanks at home. Photometric, electrometric and volume methods were usedin the respective
physical and chemical analysis; additionally for microbiological parameters was used the membrane filtration
technique. The results showed that most samples did not meet the minimum permissible value of free
residual chlorine, therefore, according to the Risk Index Water Quality Water for human consumption
(IRCA), are classified as non-unfit for human consumption. However, othermicrobiological parameters
were met including the parameters set out in Resolution 2115 of 2007. Water quality must be maintained
throughout the distribution system. Therefore, in addition to carrying out the treatment processes, the
service provider must keep a strict control of the factors that may affect water quality.
Key words: Quality of the water, drinkable water, Coliformes, Escherichiacoli, IRCA, distribution network.
206
Calidad físico-química y microbiológica del agua del municipio de Bojacá, Cundinamarca pp. 206 - 212
Introducción
Toma de muestras
La cabecera municipal de Bojacá se abastece de agua
de una fuente superficial nacedero y de un pozo, el
agua proveniente del nacedero es tratada en una planta
donde se lleva a cabo el proceso de microfiltrado y
cloración yposteriormente por bombeo, llega a la
red combinándose con el agua del pozo tratada en la
planta urbana. La cobertura del servicio de acueducto
en el área urbana es del 96% y beneficia a un total de
5904 usuarios (1).
Según la contraloría de Cundinamarca, en el periodo
comprendido entre el año 2007 y el primer trimestre
del 2008, la mayor parte de los acueductos en los
municipios de Cundinamarca...