Obtencion de gasto de filtracion
a) Red de flujo 1.
Datos:
k | 3x10-5 cm/seg |
ϕ | 1000 cm |
nt | 4 |
ne | 3 |
L | 100 m |
Q=k*ϕ*ntne
Q=3x10-5*1000*43*100
Q=4 cm/ seg /m.LQT=100*4*86400seg/dia*365dias/año1000000 cm3/m3
QT=12614.4 m3/año
Φ=10m
b) Red deFlujo 3.
Datos:
k | 3x10-5 cm/seg |
ϕ | 1000 cm |
nt | 4 |
ne | 8 |
L | 100 |
Q=k*ϕ*ntne
Q=3x10-5*1000*48*100
Q=1.5 cm/ seg /m.LQT=100*1.5*86400seg/dia*365dias/año1000000 cm3/m3
QT=4730.4 m3/año
Φ=10m
c) Red de flujo 5.
Datos:
k | 3x10-5 cm/seg |ϕ | 1000 cm |
nt | 3 |
ne | 15 |
L | 100 |
Q=k*ϕ*ntne
Q=3x10-5*1000*315*100
Q=0.6 cm/ seg /m.L
QT=100*0.6*86400seg/dia*365dias/año1000000 cm3/m3
QT=1892.16 m3/añoΦ=20m
d) Red de flujo 2.
Datos:
k | 3x10-5 cm/seg |
ϕ | 2000 cm |
nt | 4 |
ne | 15 |
L | 100 |
Q=k*ϕ*ntne
Q=3x10-5*2000*415*100
Q=1.6. cm/ seg /m.LQT=100*1.6*86400seg/dia*365dias/año1000000 cm3/m3
QT=5045.76 m3/año
Φ=30m
e) Red de Flujo 4.
Datos:
k | 3x10-5 cm/seg |
ϕ |3000 cm |
nt | 3 |
ne | 12 |
L | 100 |
Q=k*ϕ*ntne
Q=3x10-5*3000*312*100
Q=2.25 cm/ seg /m.L
QT=100*2.25*86400seg/dia*365dias/año1000000 cm3/m3
QT=7095.6 m3/año...