P3000

Páginas: 9 (2186 palabras) Publicado: 3 de agosto de 2012
Product Reference
Manual

P3000-1
Penetrator Systems

2

P3000-1 Penetrator System

3

Components:
1.
2.
3.
4.
5.
6.
7.

Features:

4
1

5

P3000-1 Feed-thru Assembly
Canned Pump Coupling (CPC)
Bracket Assembly
Surface Conduit System
Breather Vent / Detonation Arrestor
Cable Gland
Surface Power Cable (CLX)

6






7




Eliminates cablesplices in the wellbore.
Adaptable with either concentric or eccentric wellhead completions, and can
be run in small annular spaced wells.
ESP cable is stripped and the three cable wires are separated and sealed off
with an elastomer sealing element.
Three flexible fittings with Swagelok connections seal off the penetrator
above and below the tubing hanger.
Reusable explosion proof CPC andConduit system suitable for hazardous
locations.
UL listed surface cable (CLX) is terminated and sealed in the surface conduit
system for a required length to reach the power supply.
Permits the use of shielded or non-shielded cable.

Specifications:







FM & CSA Approved
Voltage: Dependent on Max. Rating of ESP Cable
Amperage: Dependent on Max. Rating of ESP CablePressure: 3,000 psi API WP (6,000 psi Proof Test)
Temp: 375°F, 190°C
Hazardous Area: Class 1, Divisions 1 & 2 Group D

P3000-1

Feed-thru Assembly
&
Rerun Kit (P/N RR-P1)

P3000-1

2

P3000-1FR Penetrator System

3

Components:
1.
2.
3.
4.
5.
6.
7.
8.

Features:

4
1

5

6






1

Flat-to-round Transition Collar
P3000-1 Feed-thru Assembly
Canned PumpCoupling (CPC)
Bracket Assembly
Surface Conduit System
Breather Vent / Detonation Arrestor
Cable Gland
Surface Power Cable (CLX)

7





Eliminates cable splices in the wellbore.
Adaptable with either concentric or eccentric wellhead completions, and can
be run in small annular spaced wells.
ESP cable is stripped and the three cable wires are separated and sealed off
with anelastomer sealing element.
Three flexible fittings with Swagelok connections seal off the penetrator
above and below the tubing hanger.
Reusable explosion proof CPC and Conduit system suitable for hazardous
locations.
UL listed surface cable (CLX) is terminated and sealed in the surface conduit
system for a required length to reach the power supply.
Permits the use of shielded or non-shieldedcable.

Specifications:







FM & CSA Approved
Voltage: Dependent on Max. Rating of ESP Cable
Amperage: Dependent on Max. Rating of ESP Cable
Pressure: 3,000 psi API WP (6,000 psi Proof Test)
Temp: 375°F, 190°C
Hazardous Area: Class 1, Divisions 1 & 2 Group D

P3000-1FR

Feed-thru Assembly
&
Rerun Kit (P/N RR-P1FR)

P3000-1FR

2

P3000-1F Penetrator System

3Components:
1.
2.
3.
4.
5.
6.
7.

4
1

5

P3000-1 Flat Feed-thru Assembly
Canned Pump Coupling (CPC)
Bracket Assembly
Surface Conduit System
Breather Vent / Detonation Arrestor
Cable Gland
Surface Power Cable (CLX)

Features:
6





7






Eliminates cable splices in the wellbore.
Adaptable with either concentric or eccentric wellhead completions,and can
be run in small annular spaced wells.
ESP cable is stripped and the three cable wires are separated and sealed off
with an elastomer sealing element.
Three flexible fittings with Swagelok connections seal off the penetrator
above and below the tubing hanger.
Reusable explosion proof CPC and Conduit system suitable for hazardous
locations.
UL listed surface cable (CLX) is terminatedand sealed in the surface conduit
system for a required length to reach the power supply.
Permits the use of shielded or non-shielded cable.

Specifications:







FM & CSA Approved
Voltage: Dependent on Max. Rating of ESP Cable
Amperage: Dependent on Max. Rating of ESP Cable
Pressure: 3,000 psi API WP (6,000 psi Proof Test)
Temp: 375°F, 190°C
Hazardous Area: Class 1,...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • 015 Inteligencias Multiples P3000 2013

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS