PAC TRACE MDC 8-9.TXT LOGIN ****** Access level set to : Technician OK. PAC>TIME The current GMT time is : Wed Jan 2 16:32:07 2013 OK. PAC>SI *** System Information 01/02/13 16:32:10 GMT *** Version 4.01 Build 0306 SN:400000D069434D74 Run level Access level MAC address IP address : : : : (0) In Service Technician 00.D0.69.43.4D.74 0.0.0.0 1168 Kb 13.29 V 33.00 C 343938993 00110 1 00:52:06 ) TX(365792 ) TX( 24487 ) : CONNECTED : Primary : 172.31.1.193 : 0 bytes : 0 # Sent : 0 # Received : 0 # Failed

Memory Usage : Supply Voltage : Board Temp : Ticks : Jumpers : Up Time : RTU : RX( 281302 NET : RX( 7027 ) NET : Status : Server : IP Local Message Queue # On Hold # Pending # Intransit

: 79 (17276 bytes) : 1 (11 bytes) : 0

OK. PAC>NETST OK. PAC>Request Net Status...OK. Net statusreceived. SH   PAC>SH TRACE app:4 rtu:5 net:5 ssn:2 ppp:4 ticks:0 PAC RPTOffset 0 LOWpower OFF TAG 0 TIMEZone 0 AWAKE 35 LOGGING OFF RUNLevel 0 POWersave 0 IO IPDelay 0 IWDelay 0 BOTimer 0 BOCount 2 ETHernet POWer ON DHCP ON RTU TYpe MBP DEBug OFF MODE RTU MAXRetries 2 RXTimeout 1 COMM Page 1

PAC TRACE MDC 8-9.TXT PORT BAud DAtabits PArity STopbits NET TYpe NRA DEBug ON CONNECT ATDT INITATE0V1&C1&D2&S2+WS45=4 PRImary 2 SECondary 2 DSRTimeout 120 REGister OFF VERSION 53 SIGNAL 596 OCEANRGN 0 SPOTBEAM 3 FWDID 002AB10D COMM POrt COM2 BAud 38400 DAtabits 8 PArity None STopbits 1 PROtocol DEBug OFF MAXRetries 3 RXTimeout 90 TXTimeout 60 MAXPacket 1024 MSG MAXRetries 240 TImeout 30 WATchdog 720 SESsion TImeout 0 MAXRetries 6 FAILover 3 REDial 60 MAXFAILure 12 WAWI Enable OFF Local0.0.0.0:0 Remote 192.23.19.129:2100 IP Enable ON Local 0.0.0.0:2100 Remote 192.23.19.129:2100 PPP Enable ON DOMAIN @wrx1.net PSWD wrxslb TImeout 1800 OK. PAC>EVENT LIST Pollset Poll Report Index Pid Start Time Interval Interval -------+-----+-------------------+-------------+-------------+ 1 : 1 01/01/80 15:00:00 00 00:03:00 00 01:00:00 2 : 3 01/01/80 15:00:00 00 00:03:00 00 01:00:00 3 : 5 01/01/8015:00:00 00 00:03:00 00 01:00:00 4 : 254 01/01/80 15:00:00 00 00:03:00 01 00:00:00 Page 2 COM4 9600 8 None 1

16

: 255

PAC TRACE MDC 8-9.TXT 05/12/12 00:38:29 07 00:00:00 07 00:00:00

Event Start Time Interval -------------+-------------------+------------NetStatus : 01/01/80 15:00:05 00 01:00:00 TimeSync : 01/01/80 14:00:00 01 00:00:00 HeartBeat : Disabled OK. PAC>PAC: Begin Pollset [1][01/02/13 16:33:00] RTU Read [ 51] : Timeout RTU Read [ 69] : Timeout PAC: Rtu timeout limit reached. Disabling RTU 1 RTU Read [ 70] : Disabled RTU Read [ 71] : Disabled RTU Read [ 72] : Disabled RTU Read [ 73] : Disabled RTU Read [ 78] : Disabled RTU Read [ 79] : Disabled RTU Read [ 80] : Disabled RTU Read [ 81] : Disabled RTU Read [ 82] : Disabled RTU Read [ 83] : Disabled RTU Read [ 84] : DisabledRTU Read [ 85] : Disabled RTU Read [ 86] : Disabled RTU Read [ 87] : Disabled RTU Read [ 88] : Disabled RTU Read [ 89] : Disabled RTU Read [ 92] : Disabled RTU Read [ 93] : Disabled RTU Read [ 94] : Disabled RTU Read [ 95] : Disabled RTU Read [ 96] : Disabled RTU Read [ 99] : Timeout RTU Read [917] : Timeout PAC: Rtu timeout limit reached. Disabling RTU 2 RTU Read [925] : Disabled RTU Read [930] :Disabled RTU Read [935] : Disabled RTU Read [950] : Disabled RTU Read [951] : Disabled RTU Read [963] : Disabled RTU Read [967] : Disabled RTU Read [972] : Disabled RTU Read [973] : Disabled RTU Read [974] : Disabled RTU Read [975] : Disabled RTU Read [976] : Disabled PAC: Poll complete. PAC: Begin Pollset [3] [01/02/13 16:33:12] RTU Read [1070] : 206 RTU Read [1075] : 22828 RTU Read [1076] :18766 RTU Read [1078] : 4349 RTU Read [1083] : 2226 RTU Read [1088] : 2676 RTU Read [1093] : 108 RTU Read [1098] : 300 RTU Read [1102] : 585 RTU Read [1103] : 6350 RTU Read [1105] : 522734 Page 3

PAC TRACE MDC 8-9.TXT RTU Read [1115] : 33181 RTU Read [1119] : 4488 RTU Read [1121] : 0 RTU Read [1122] : 0 RTU Read [1123] : 0 RTU Read [1124] : 0 RTU Read [1128] : OFF RTU Read [1129] : ON RTU Read...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • MUNDO INTERNO TOMAS NAGEL
  • Valores En La Toma De Decisiones
  • El Valor De La Comunicacion Interna
  • El rol de los valores en la toma de decisiones
  • Valor agregado de Auditoría interna
  • Los valores mas tomados en cuenta
  • Factores Internos en la toma de Decisión Profesional
  • Distorsiones del control interno toma de inventarios

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS