Problemas de instalaciones de gas
Tramo AB
Datos
G= 0.318 + 0.239 + 0.418 = 0.975
L= 7.30
F= ¾ CR-L= 0.048
H AB= (0.975)² (7.3) (0.048)= 0.33Tramo BC
Datos
G= 0.418 +0 .239 = 0.657
L= 6.30
F= 1/2 CR-L= 0.970
H BC= (0.657)² (6.30) (0.970)= 2.63
Tramo CD
Datos
G= 0.418
L= 1.50
F= 1/2 C-FLEX= 0.970
H CD= (0.418)² (1.50)(0.970)= 0.254
TRAMOS:
AB - 0.33
BC - 2.63
CD - 0.254
TOTAL = 3.22
3.22 < 5%
Y POR LO TANTO LA INSTALACION ES BUENA
“Calculo de la máxima caída de presión en la instalaciónde gas”
Tramo AB
Datos
G= .318+.650+.239= 1.207
L= 4.00m
F= .297 F=1/2” RC-L
H AB= (1.207)²(4)(.297)= 1.730
Tramo BC
Datos
G= .239 +.650= .889
L= 3.00 m
F= .297F=1/2” CR-L
H BC= (.889)²(3)(.297)= .704
Tramo CD
Datos
G= .650
L= 1.00m
F=.297 F=1/2” CR-L
H CD= (.650)²(1)(.297)=.125
Tramo DE
Datos
G= .650
L=1.50
F=.970F=1/2” C.flex.
H DE= (.650) ² (1.50)(.970)= .614
TRAMOS:
AB - 1.730
BC - .704
CD - .125
DE - .614
TOTAL = 3.173 %
3.173 < 5%
Y POR LO TANTO LA INSTALACION ES SATISFACTORIA“Calculo de la máxima caída de presión en instalación de gas”
TRAMO AB
Datos
G= 0.239m³/h +0.480 m³/h= 0.719 m³/h
L= 5.00mLa tubería que se puedes utilizar para mayor ventaja es tubería de cobre rígido de 12.7mm cuyo factor es de 0.297. Para calcular la presión real del tramo.
F= ½” de Diámetro CR-LF=0.297
h= G² L F
h AB = 0.719 m³/h)(5.00m)(0.297)= 0.768
TRAMO BC
Datos
G=0.480 m³/h
L= 2.70m
F= ½” de Diámetro CR-L F=0.297
h BC = (0.480 m³/h)(2.70m)(0.297)= 0.384TRAMO CD
Datos
G=0.480 m³/h
L=1.5m
F= ½” de Diámetro C. FLEX F=0.297
h CD = (0.480 m³/h)(1.50m)(0.297)= 0.1026
TRAMOS:
AB - .768
BC - .384
CD - .1026
TOTAL = 1.25%
1.25< 5%
Y POR...