Sensor Infrarrojo LC100

Páginas: 8 (1785 palabras) Publicado: 27 de marzo de 2012
LC-100PI
PIR Motion Detector with Pet Immunity up to 25kg
Installation Instructions
The LC-100PI detector uses a special designed optical Lens with unique Quad (Four element) PIR Sensor and new ASIC based electronics optimized to eliminate false alarms, caused by small animals and Pets. The LC100PI provides unprecedented levels of immunity against visible light. The Detector offers anexceptional level of detection capability and stability for every security installation. The LC-100PI is supplied with Wide Angle lens. The LC-100PI provides Pet immunity up to 25Kg (55 lbs). For better immunity avoid installation in areas where pets can reach upwards. TYPICAL INSTALLATION Select mounting location Choose a location most likely to intercept an intruder. See detection pattern(Fig.5). TheQuad high quality sensor detects motion crossing the beam; it is less sensitive detecting motion towards the detector. The LC-100PI performs best when provided with a constant and stable environment. Avoid the following locations * Facing direct sunlight. * Facing areas subject to rapid temperature changes. * Areas with air ducts or substantial air flows. MOUNTING THE DETECTOR 1. To remo ve th efron t co ver (Fi g .4), un screw th e h ol d in g scre w (Fi g .4-11 ) an d g e nt ly ra ise the fro nt cove r. 2. To remove th e PC b oa rd, carefu ll y u nscrew th e h ol di ng screw (Fi g.4 -9) l oca ted o n t he PC bo ard (Fig .4-1 0). 3. Break out the desired holes (Fig.2-B or C) for proper installation (flat or corner). 4. The circular and rectangular indentations at the bottom base are theknockout holes (Fig.2-D) for wire entry. You may also use mounting holes that are not in use for running the wiring into the detector.(For option with bracket (Fig.1 & 3)(Fig.4-7), lead wire through the bracket) 5. Mount the detector base to the wall, corner or ceiling. (For options with bracket install bracket). 6. Reinstall the PC board by fully tightening the holding screw. Connect wire toterminal block. 7. R ep l ace th e cove r b y in se rti ng i t ba ck in t he a p pro p ri at e clo si ng pi n s a nd scre w i n th e h ol d in g scre w. DETECTOR INSTALLATION Terminal block connections (Fig.6) Terminals 1 & 2 - Marked T2 and T1 (TAMPER) If a Tamper function is required connect these terminals to a 24-hour normally closed protective zone in the control unit. If the front cover of thedetector is opened, an immediate alarm signal will be sent to the control unit. Terminals 3 & 4 - Marked NC and C (RELAY ) These are the output relay contacts of the detector. Connect to a normally closed zone in the control panel. Terminal 5 - Marked “ EOL ” End of line option. Terminal 6 - Marked “ - ” (GND) Connect to the negative Voltage output or ground of the control panel. Terminal 7 - Marked“ + ” (+12V) Connect to a positive Voltage output of 8.2 -16Vdc source (usually from the alarm control unit).
1 3

FIG 3 - Bracke t options

15m

1

1 3 7

Wall Mo unt Br acket

2

Ceiling Mount Bra cket

FIG 1 - Bracket Installa tion FIG 2 - Knockout h oles
A C A C

4 8

5 9 10

B

D

D

B C

FIG 5 - Lens pattern
T2 T1 NC C EOL - 12V +

6

C

B

B

CFIG 4 - Dete ctor In stallation

11

1

2

3

4

5

6

7

FIG 6 - Terminal block

SETTING - UP THE DETECTOR PULSE WIDTH JUMPER SETTING
3 2 1 PULSE

Very stable environment Position 1 Without PET

3 2 1 PULSE

Moderate nuisance situation Position 2 PET up to 15Kg (33.1 Ib)

3 2 1 PULSE

Relatively high change of false alarms Position 3 PET up to 25Kg (55 Ib)

LEDENABLE JUMPER SETTING LED ON LED OFF

PET IMMUNITY JUMPER SETTING
PET 25Kg 15Kg

Immunity to an animal up to 15Kg (33.1 Ib)

PET

25Kg 15Kg

Immunity to an animal up to 25Kg (55 Ib)

PIR sensitivity adjustment POTENTIOMETER “SENS”– adjustment according to protected area range. Use the potentiometer to adjust the detection range between 68% and 100% (factory set to 84%). Rotate the...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • Sensor infrarrojo
  • Sensor infrarrojo
  • Sensor infrarrojo
  • Sensor Infrarrojo
  • Sensores infrarrojos
  • Sensor infrarrojo
  • Sensor infrarrojo
  • Sensor infrarroja reflex

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS