Tabla de calibracion de tanques

Páginas: 35 (8750 palabras) Publicado: 27 de noviembre de 2011
PETROSPECTION Pty Ltd

ELECTRONIC TABLE
ACN 063 402 424

Uncontrolled Copy

Western Australia 8 Edison Circuit, Rockingham WA 6168 Tel (08) 9528 1888 Fax (08) 9528 1588 mail@petrospection.com.au www.petrospection.com.au

Page 1 of 11 Reference: PS060000

Company Name EXAMPLE Tank ID Terminal Name

Date of Calibration

02/03/06

Calibration performed and calculated in accordancewith ISO Standard 7507

NATA Accredited Laboratory Number: 9475 The tests, calibrations or measurements covered by this document have been performed in accordance with NATA requirements which include the requirements of ISO/IEC 17025 and are traceable to Australian national standards of measurement. This document shall not be reproduced, except in full. STEPHEN FORD

Authorised Signatory

Theofficial version of the calibration table is a signed hardcopy.

PETROSPECTION Pty Ltd

ELECTRONIC TABLE
ACN 063 402 424

Uncontrolled Copy
Page 2 of 11

Western Australia 8 Edison Circuit, Rockingham WA 6168 Tel (08) 9528 1888 Fax (08) 9528 1588 mail@petrospection.com.au www.petrospection.com.au

Company Name EXAMPLE Tank ID - Terminal Name
CERTIFICATE OF CALIBRATION - N0. PS060000This table gives volumes in litres for millimetres of product measured over the dip plate. The tank is a vertical "in/out" lapped tank with a fixed roof, an internal blanket and a coned up floor. The first red highlighted area on page 4 of the table is below the high point of the floor. In this zone the average values from the bottom of the page should not be used. Intermediate volumes in thezone should be interpolated from the nearest values in the table. Accurate volumes cannot be obtained from the tables within the zone of partial displacement of the blanket, which is also highlighted in red on the table. Refer to the Floating Blanket Correction Table (page 3) for the zone levels and treatment of the blanket in the calculation of tank volumes. Tank dimensions: Diameter (external atbase): Shell height: Maximum Safe Fill height: Capacity at M.S.F. height: 20.015 14.145 12,280 3,858,099 metres metres mm litres

Reference height: The tank has been calibrated for a temperature of: Manual gauging dip plate above shell bottom edge (average height): Heights of tank fittings relative to dip plate Manholes (2 of) 150NB Inlet 200NB Outlet 100NB Jet Mixer 200NB Foam Line bases exposedat: covered at: covered at: covered at: covered at:

15,545 mm 15 deg C 139 mm 380 380 470 560 520 mm mm mm mm mm

A 100NB Water Drain draws from a sump located adjacent to the tank shell.
Volume below datum plate calibrated by phys ical s urvey. T ank volumes have been calculated us ing the following factors :Young’s Modulus : Coefficient of linear expans ion of the tank s hell metal:Calibration T ape Certification T emperature: Coefficient of linear expans ion of the s trapping tape metal: T ank s hell expans ion under liquid head calculated at dens ity: No adjus tment has been incorporated into this table for product menis cus effect on dip tape readings . All meas urements are traceable to Aus tralian national s tandards . S hell plate thicknes s es meas ured on s ite.2,040,000 0.000011 20 0.000011 0.7400

kg/cm2 /Deg C Deg C /Deg C kg/litre

Calibration Performed: Certificate is s ued: Calibration to:

02/03/06 14/09/06 IS O S tandard 7507

F or and on behalf of PETROSPECTION Pty Ltd

The official version of the calibration table is a signed hardcopy.

PETROSPECTION Pty Ltd

ELECTRONIC TABLE
ACN 063 402 424

Uncontrolled Copy

Western Australia 8Edison Circuit, Rockingham WA 6168 Tel (08) 9528 1888 Fax (08) 9528 1588 mail@petrospection.com.au www.petrospection.com.au

Page 3 of 11 Reference: PS060000

Company Name EXAMPLE Tank ID - Terminal Name FLOATING BLANKET CORRECTION TABLE
This tank is equipped with a floating blanket, the weight of which has been given to us as: Between the following dips the blanket is only partially...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • Calibracion De Tanques
  • Calibracion De Tanques
  • Calibracion De Tanques De Petroleo
  • Calibracion De Tanques Y Recipientes
  • Tanque
  • tanques
  • Tanques
  • Tanques

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS