Detección No Invasiva de Niveles de Glucemia a través de Espectroscopía de Inducción Magnética: Estudio de Viabilidad en Pacientes Diabéticos

Cadete Olivia Eugenia Rodríguez-Rodríguez*, Cadete Martha Elena Florencia-Emilio *, Cadete Ana Raquel Castillo-Regalado*, Myr. M.C. Salvador Polo-Soto**, Tte. Cor. M.C. Sergio Martínez-Salas** y Cap. 1/o. I.C.E César Antonio González-Díaz**

*Escuela Médico Militar-Universidad del Ejército y Fuerza Aérea. México. **Escuela Militar de

Graduados de Sanidad-Universidad del Ejército y Fuerza Aérea. Laboratorio Multidisciplinario de Investigación-Area de Bioingeniería. México.

Correspondencia: Cap 1/o. I.C.E. César Antonio González Díaz Escuela Militar de Graduados de Sanidad Universidad del Ejército y Fuerza Aérea, Cda. de

Palomass/n esq. c/periférico, Col Lomas de San Isidro, C.P. 11200, México D.F. Correo electrónico: c.cesar.gonzalez@gmail.com

Título abreviado: Viabilidad Glucómetro Inductivo Experimental.

RESUMEN El presente estudio evalúa la viabilidad de la Espectroscopia de Inducción Magnética (EIM) como técnica no invasiva para la determinación de niveles de glucemia en tejido biológico. Se realizaronmediciones de la concentración de glucosa en pacientes diabéticos normo e hiperglucémicos utilizando un glucómetro comercial de bandas reactivas. Los valores de glucemia se asociaron con mediciones de EIM realizadas en el volumen del dedo índice del paciente. Las mediciones de EIM se realizaron empleando un espectrómetro inductivo experimental cuyo mesurado es el corrimiento de fase inductivo amúltiples frecuencias. La viabilidad de la técnica de EIM como método de medición de la concentración de glucosa se evaluó utilizando análisis de correlación lineal y técnicas de exploración multivariada. Los resultados indican que es posible identificar diferentes niveles de glucemia a través de mediciones del corrimiento de fase inductivo a frecuencias específicas inferiores a 1 MHz. Aún se requierenestudios futuros relativos al análisis de patrones característicos del espectro de corrimiento de fase inductivo asociados a la concentración de glucosa.

SUMMARY This work describes a viability study of Magnetic Induction Spectroscopy (MIS) as a non invasive technique to determine different glucose levels in biological tissue. Glucose concentrations were measured in euglycemic and hyperglycemicdiabetic patients by a commercial glucometer device. The glycemic values were associated to MIS measurements taken in a volume of the patient´s finger. The MIS measurements were developed by an experimental inductive spectrometer which detects the inductive phase shift at multiple frequencies. The viability of the MIS technique to determine glucose concentrations was evaluated by linealcorrelation and multivariate exploration techniques. The results show the possibility to identify different glycemic levels by inductive phase shift measurements at specific frequencies below 1MHz. Further studies regarding the analysis of the characteristic inductive phase shift patterns associated to the glucose concentration are warranted.

INTRODUCCIÓN La Diabetes Mellitus tipo 2 (DM2) es unproblema relevante de salud pública, de acuerdo con la información disponible, en 1995 el país ocupaba el décimo lugar mundial con 4 millones de enfermos, y se estima que para el 2025 ocupará el séptimo con 12 millones [1].

Las limitaciones actuales en el tratamiento de la DM2 están asociadas al diagnóstico tardío de la enfermedad, así como a la imposibilidad de monitorear continuamente larespuesta terapéutica. Actualmente existen tecnologías mínimamente invasivas que permiten el monitoreo continuo de los niveles de glucosa, sin embargo, tienen una serie de desventajas como la necesidad de colocar los sensores con el auxilio de un profesional de la salud, los sensores tienen periodos de vida útil relativamente cortos entre tres y cinco días, posibles efectos secundarios relacionados a...