Calibracion

Páginas: 36 (8932 palabras) Publicado: 7 de marzo de 2013
EAL

European cooperation for
EAL-G17 Z C MM CALIBRATION
Accreditation of Laboratories

Publication Reference
WELAC Guidance Document WGD 8

EAL-G17

Coordinate Measuring Machine
Calibration

PURPOSE
This document has been produced by EAL to provide information on the measurement
capabilities of coordinate measuring machines (CMMs) and the treatment of measured
data, and toprovide guidance to national accreditation bodies accrediting laboratories
to perform task-related calibrations of CMMs, or to use CMMs for the calibration of
components.
EDITION 1 Z J ANUARY 1995

P AGE 1 OF 28

E AL-G17 Z C MM CALIBRATION

Authorship
This publication has been written by the EAL Expert Group Dimensional Metrology working group
on CMMs.
Official language
The text may betranslated into other languages as required. The English language version remains
the definitive version.
Copyright
The copyright of this text is held by EAL. The text may not be copied for resale.
Further information
For further information about this publication, contact your National member of EAL, whose telephone
and facsimile numbers are given below:
Calib National member TestingNational
member
Austria

Belgium

Denmark

Finland

France

Germany

Greece

Iceland

Ireland

Calib National member
member

BMwA
Tel: +431 711 02 233
Fax: +431 714 35 82

BMwA
Tel: +431 711 02 249
Fax: +431 714 35 82

BKO/OBE
Tel: +322 233 6111
Fax: +322 230 8300

BELTEST
Tel: +32 2 548 15 11
Fax: +32 2 514 47 56

DANAK
Tel: +45 35 86 86 86
Fax: +45 35 86 86 87DANAK
Tel: +45 35 86 86 86
Fax: +45 35 86 86 87

FINAS
Tel: +358 0 61671
Fax: +358 0 6167 467

FINAS
Tel: +358 0 61671
Fax: +358 0 6167 467

Italy

Fax: +353 1 368 738
SIT
Tel: +39 11 348 8933
Fax: +39 11 34 6384

Testing National
Fax: +353 1 368 738
SINAL
Tel: +39 6 487 1176
Fax: +39 6 481 4563

Netherlands NKO/STERIN/STERLAB NKO/STERIN/STERLAB
Tel: +31 10 413 6011Tel: +31 10 413 6011
Fax: +31 10 413 3557
Fax: +31 10 413 3557
Norway

NA
Tel: +47 22 20 0226
Fax: +47 22 20 7772

NA
Tel: +47 22 20 0226
Fax: +47 22 20 7772

Portugal

COFRAC
COFRAC
Tel: +33 1 44 68 82 20 Tel: +33 1 44 68 82 20
Fax: +33 1 44 68 82 21 Fax: +33 1 44 68 82 21

IPQ
Tel: +351 1 52 3978
Fax: +351 1 3153676

IPQ
Tel: +351 1 52 3978
Fax: +351 1 3153676

SpainDKD
DAR
Tel: +49 531 592 8320 Tel: +49 30 8104 1710
Fax: +49 531 592 9292 Fax: +49 30 8104 1717

SCI
Tel: +34 1 349 4711
Fax: +34 1 457 8066

RELE
Tel: +34 1 564 96 87
Fax: +34 1 563 04 54

Sweden

SWEDAC
Tel: +46 33 17 7700
Fax: +46 33 10 1392

SWEDAC
Tel: +46 33 17 7700
Fax: +46 33 10 1392

Ministry of Commerce
Tel: +30 1 36 14 168
Fax: +30 1 36 42 642

ELOT
Tel:+30 1 201 5025
Fax: +30 1 202 0776

ISAC
Tel: +354 1 681 122
Fax: +354 1 685 998

ISAC
Tel: +354 1 681 122
Fax: +354 1 685 998

ICLAB
Tel: +353 1 370 101

ICLAB
Tel: +353 1 370 101

PAGE 2 OF 28

Switzerland SAS SAS
Tel: +41 31 963 3111
Fax: +41 31 963 3210

Tel: +41 31 963 3412
Fax: +41 31 963 3210

United Kingdom NAMAS
Tel: +44 181 943 7068
Fax: +44 181 943 7134NAMAS
Tel: +44 181 943 6266
Fax: +44 181 943 7134

EDITION 1 Z J ANUARY 1995

EAL-G17 Z C MM CALIBRATION

Contents
Section

Page

1

Summary

4

2

Introduction

4

3

Calibration and performance verification of CMMs

5

4

Accreditation of calibration laboratories

6

5

Calibration procedures

7

6

Calibration certificates

10

7

Future

118

References

11

Appendix A

Terms and definitions

13

Appendix B

Accreditation of laboratories for the calibration of CMMs

16

Appendix C

Accreditation of laboratories for calibration of artefacts
using CMMs

17

Appendix D Comparator approach

18

Appendix E

Error synthesis approach

20

Appendix F

Recommendations for future developments

27...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • calibración
  • Calibracion
  • Calibracion
  • Calibracion
  • Calibracion
  • Calibracion
  • Calibracion
  • Calibración

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS