Control Presion A10Vso Rexroth
Pressure port B Case drain port L Pressure control DR Standard setting: A10VODFR/31: 280 bar A10VODFR/52: 250 bar Flow control FR (∆p = 10 - 22 bar) Standard setting: ∆p = 14 bar X - Pilot pressure port Suction port S
(viewed A10VO, BR 31, clockwise)
A10 146.e/VST6/H 01.AK
A10V(S)O Pressure/Flow control DFR(1) Circuit diagram
Adjustableorifice, (6) res. Mobile valve block (not included in supply)
9 3 2 7
FR
X - port Flow control (Standard: ∆p = 14 bar); Spring force (5)
4
1
DR
Decompression orifice Pressure spring Damping orifice
Control piston (8)
(Circuit diagram viewed for A10VO, series 31)
A10 146.1.e/VST6/H 01.AK
Bias piston and spring
A10V(S)O Pressure/Flow control DFR(1) Circuit diagram
Adjustableorifice, res. Mobile valve block (not included in supply) FR X - port Flow control (Standard: ∆p = 14 bar); Decompression orifice Pressure port Damping orifice
DR
Control piston
(Circuit diagram viewed for A10VO, series 31) Counter balance piston and mechanical spring
A10 146.2.e/VST6/H 01.AK
A10V(S)O Pressure/Flow control DFR(1) Function and circuit diagram
Orifice res. Mobile valveblock LS - pilot pressure
X
FR
DR
DR - axis FR - axis
X
A10 146.3.e/VST6/H 01.AK
A10V(S)O Pressure/Flow control DFR(1) ∆p - control characteristic f (x) = (px, Vg)
High pressure: p HD Simulated load pressure: p X
220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 0 25 50 75 100 Fördermenge in
∆p = 15 bar
A10 VO 74 DFR(1)
Mode ofexperimental procedure:
n = 1500 rpm ∆p = 15 bar Stand by = 20 bar
pHD
X DFR1
px
A10 146.4.d/VST6 01.AK
A10V(S)O Pressure/Flow control DFR(1) Decompression orifice and damping orifice
DFR with decompression orifice:
(DFR: Standard: ∅ 0,35 mm) (DFR1: closed, without drilling)
X
FR
FR - axis
DR
DR - axis
Damping orifice DR - FR
(Standard: ∅ 0,6 mm, Slit in longitudinaldirection: orifice opened Slit in cross direction : orifice closed, SO 74)
A10 146.5.e/VST6/H 01.AK
A10V(S)O Pressure/Flow control DFR(1) Damping orifice
Damping orifice DR - FR
(Standard: ∅ 0,6 mm, Slit in longitudinal direction: orifice opened Slit in cross direction
p [bar] 250
: orifice closed, (SO 74)
250,0
pressure increase of the valve (pHD = 200 bar)
closed open
200200,0
150
150,0
100
100,0
50
50,0
0 0,000
0,050
0,100
0,150
0,200
0,250
0,300
0,350
0,400
0,450
0,0 0,500 x [m m ] adjusting path of the piston
A10 146.6.e/VST6/H 01.AK
A10V(S)O Pressure/Flow control DFR(1) Measurement of high pressure
Attention: The mini - measurement connection have to be shortened according to the original lenght of theplug (reach of a screw 7 mm).
Measurement high pressure: At this particular spot, the existing plugs (M8 x 1) can be replaced by mini measurement connections
A10 146.7.e/VST6/H 01.AK
A10V(S)O Pressure/Flow control DFR(1) Adjustment for pressure- res. flow control
Adjustment of pressure control Adjustment of flow control: „Stand - by“ pressure measurement or Differential pressuremeasurement with swivel angle !
Valve axis: Pressure control
A10 146.8.e/VST6/H 01.AK
Valve axis: Flow control
A10V(S)O Pressure/Flow control DFR(1) Adjustment of pressure control DR
Procedure: ⇒ FR - flow control blocked ! ⇒ High pressure line closed ! ⇒ Adjusting of DR pressure control with setting value ! Measuring - point 1: High pressure (measurable at plug of DR valve axis) Adjustment DR: each rotation app. 50 bar !
FR
X
DR
- 50 bar + 50 bar
A10 146.9.e/VST6/H 01.AK
A10V(S)O Pressure/Flow control DFR(1) Adjustment of flow control FR
1. „Stand by“ pressure measurement: Procedure: ⇒ X - port unloaded to tank ! ⇒ close high pressure port ! Standard adjustment FR ∆p = 14 bar (When port X is unloaded to tank, a zero stroke pressure of p = 16 ± 1 bar „stand by“...