1 Specifications cont.

Premier Series

Non-Programmable Thermostats
MODEL

3000
MODEL

3200

Single Stage Heat / Cool
Conventional and Heat Pump

2 Installation

Multi-Stage 2 Heat / 2 Cool

Replacing Existing Thermostat

Conventional and Heat Pump

1. Always turn off power to the air conditioning or heating system prior to
removing existing thermostat.
2. Remove thecover of your old thermostat and locate the wire terminals.
Do not remove wires from terminals until step 3 is completed.
3. Using small pieces of masking tape, label wires prior to removal from
terminals. Use the chart below to determine the new terminal designations
for your new thermostat.

Before Installing, Programming or Operating,
PLEASE READ ALL INSTRUCTIONS
1
2
3
4
5

• Model3000: Compatibility with low voltage single stage gas, oil or electric
heating or cooling systems, including single stage heat pumps; can also
be used on 250mv to 750mv millivolt heating only systems.
• Model 3200: Compatibility with low voltage multi-stage gas, oil or electric
heating or cooling systems, including multi-stage heat pumps.
• Terminations, Model 3000: Rc, Rh, B, O, Y, W, G, CTerminations, Model 3200: R, O, B, C, Y1, Y2, E/W1, W2, G, L

Specifications
Installation
Testing Your New Thermostat
Programming User Settings
Temperature Adjustment

6 Additional Operation

Features
7 Battery Replacement
8 Trouble Shooting
9 Wiring Diagrams

WARNING
Important Safety Information
• Always turn off power to the air conditioning or heating system prior to
installing,removing, cleaning or servicing thermostat.
• This thermostat requires either 24 Volts AC Power or two (2) properly installed
“AA” alkaline batteries for normal operation and control of the heating or
cooling system.
• This thermostat should only be used as described in this manual. Any other
use is not recommended and will void the warranty.

1 Specifications
• Electrical Rating: 24 VoltAC (18-30 Volt AC)
1 amp maximum load per terminal
2 amp total maximum load (all terminals) (Model 3000)
3 amp total maximum load (all terminals) (Model 3200)
• Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)
• Accuracy: +/- 1˚ F (+/- .5˚ C)
• AC Power: 18-30 Volt AC
• DC Power: 3.0 Volt DC (2 AA Alkaline batteries included)

©2011 Braeburn Systems LLC • All Rights Reserved. 3000-100-010

OldTerminal from
New Terminal for
Existing Thermostat New Thermostat
(Model 3000)

V or Rc

Rc

M, 4, Rh, or R

Rh

R, V-VR or VR-R
G or F
H, W or 4
W1, W2, W-U or E

G
W

W2
Y
Y, Y1 or M

New Terminal for
New Thermostat
(Model 3200)

Y

R
G
E/W1
W2
Y1

Y2

Y2

B

B

B

O

O

O

C

C

Terminal
Description

Cooling
Transformer
HeatingTransformer
24 VAC
Fan Control
Heating Control
Emergency Heat /
1st Stage Heat
2nd Stage Heat
Cooling Control
1st Stage
Compressor
2nd Stage
Compressor
Reversing Valve
(Heating)
Reversing Valve
(Cooling)

C

24 VAC Common

L

L or X

System Status LED

4. After labeling and removing all wires from terminals, unscrew the existing
thermostat sub-base from wall. Secure wires toprevent them from slipping into
the hole in the wall.

1

2 Installation cont.

2 Installation cont.

NOTE–MODEL 3000: This thermostat is designed for use with 24 Volt-AC low
voltage single stage gas, oil or electric heating or cooling systems, including
single stage heat pumps and can also be used on 250mv to 750mv millivolt
heating only systems. Do not use this thermostat onapplications with voltages
above 30 Volts AC.
NOTE–MODEL 3200: This thermostat is designed for use with 24 Volt-AC low
voltage multi-stage gas, oil or electric heating or cooling systems, including
multi-stage heat pump systems. Do not use this thermostat on applications with
voltages above 30 Volts AC.

Installing Your New Thermostat
NOTE: If installing this thermostat in a new installation,...