|  |ESTUDIO DE CARGA PARA EL APARTAMENTO BASE |  |
|  | | | |  |  |
|  || | |Fases |Neutros |
|CARGAS DE ILUMINACION 30w/m² x 90 | | | |2700w |2700w |
|m² | | | | ||
|CARGAS TOMAS DE USO GENERAL 180w x 16 | | | |2880w |2880w |
|CARGAS DE LAVADERO |  |  |  |1500w |1500w |
|Sub Total| | | |7080w |7080w |
|  | | | |  |  |
|APLICANDO FACTOR DE DEMANDA (TABLA 220-11 | | | | |  |
|CEN) | | | | | |
|  | | | |  |  |
|PRIMEROS 3000 AL 100 %| | | |3000w |3000w |
|EL RESTO: (4798-3000) AL 35 % |  |  |  |1428w |1428w |
|DEMANDA POR ILUMINACION ||4428w |4428w |
|  | | | |  |  |
|LAVADORA | | | |500 |500 |
| Aires/A yRefrigerador (3 x 1230w+1 x | | | |7540w |700w |
|3150w +700) | | | | | |
|CALENTADOR DE AGUA | | ||1500w |1500w |
|COCINA ELECTRICA | | | |6000w |0 |
|SECADORA (Neutro al 70%) | | | |5000w |3500w|
|25 % DEL MOTOR MAYOR |  |  |  |1250w |0 |
|DEMANDA TOTAL |  |  |26218w |10128w |
| | |...