Consumo Diesel Kta50
Columbus, Indiana 47201
Basic Engine Model:
Curve Number:
KTA50-G3
Engine Critical Parts List:
FR-6250
Date:
Page No.
ENGINE PERFORMANCE CURVEDisplacement : 50.3 litre (3067 in3 ) No. of Cylinders : 16
CPL: 2227
Stroke : 159 mm (6.25 in.)
23Apr98
Bore : 159 mm (6.25 in.)
Aspiration : Turbocharged and Aftercooled
Engine Speed RPM1500 1800
Standby Power Rating kWm 1227 1380 BHP 1645 1850
Prime Power Rating Limited Time kWm 1150 1300 BHP 1541 1742 Unlimited Time kWm 1097 1220 BHP 1470 1635
Continuous Power Rating kWm900 1000 BHP 1206 1340
Engine Performance Data @ 1500 RPM
OUTPUT POWER % kWm BHP kg/ kWm·h FUEL CONSUMPTION lb/ BHP·h litre/ hour U.S. Gal/ hour
Litre/hour
1500 RPM
STANDBY POWER 100 100100 75 50 25 100 1227 1150 1097 822 548 275 900 1645 1541 1470 1102 735 368 1206 0.203 0.202 0.202 0.206 0.216 0.234 0.204 0.334 0.333 0.333 0.338 0.355 0.385 0.336 293 274 261 199 139 76 216 77.4 72.369.0 52.5 36.6 20.0 PRIME -- LIMITED TIME RUNNING POWER PRIME -- UNLIMITED TIME RUNNING POWER
CONTINUOUS POWER 57.1
Gross Engine Power Output - kWm
CONVERSIONS:
(Litres = U.S. Gal x 3.785)(kWm = BHP x 0.746)
(U.S. Gal = Litres x 0.2642)
(BHP = Engine kWm x 1.34)
These guidelines have been formulated to ensure proper application of generator drive engines in A.C. generatorset installations. Generator drive engines are not designed for and shall not be used in variable speed D.C. generator set applications.
STANDBY POWER RATING Applicable for supplying emergency powerfor the duration of the utility power outage. No overload capability is available for this rating. Under no condition is an engine allowed to operate in parallel with the public utility at the StandbyPower rating. This rating should be applied where reliable utility power is available. A Standby rated engine should be sized for a maximum of an 80% average load factor and 200 hours of operation...