DISEÑO DE UN MURO DE HORMIGON CICLOPEO Hormigonera descanso
DISEÑO DE UN MURO DE HORMIGON CICLOPEO
ESPECIFICACIONES DEL TERRENO
DENSIDAD RELLENO =
1.8
Tn/m3
CLASE DE SULEO =
Granular
DENSIDAD DEL SUELO =
1.7
Tn/m3
ANGULO DEFRICCION =
30
grados
FACTOR DE FRICCION =
0.5
COHESION =
0
Kn/m2
Esfuerzo Admisible del Suelo =
12.403
Tn/m2
Ka =
0.333
ASENTAMIENTO ADMISIBLE
0.3
M
MATERIALES YCARGAS
HORMIGON CICLOPEO =
2.2
Tn/m3
f'c =
210
Kg/cm2
CARGA VIVA =
200
Kg/m2
SISMO =
13
%
DIMENSIONES
Altura a nivel del suelo h0=
4.2
m
Altura de cimentaciónh2 =
1.3
m
Base superior (b0) =
0.4
m
Base inferior (B) =
3.6
m
Pie (p) =
1
m
Talon (t) =
1
m
Base (b) =
1.6
m
Espesor (d)=
1
m
Altura (H) =
5.5
mFUERZAS ESTABILIZADORAS
V
X
Mr
Tn
m
Tn.m
W1
3.960
1.200
4.752
W2
5.940
1.800
10.692
W3
4.860
2.200
10.692
W4
8.100
3.100
25.110
W5
0.540
3.733
2.016
W6
7.920
1.80014.256
Totales
31.320
67.518
FUERZAS DE EMPUJE
H
Y
Mr
Tn
m
Tn.m
Ea (CM+ CV)
9.445
1.833
17.317
ANALISIS DE ESTABILIDAD
AL DESLIZAMIENTO
Factor de fricción :
0.500
Fuerzas Horizontales :
9.445
Tn
Fuerzas Verticales :
31.320
Tn
Comprobación
F.S. =
1.658
> 1.5
CUMPLE
AL VOLCAMIENTO
Momentosestabilizadores :
67.518
Tn.m
Momentos de empuje:
17.317
Tn.m
Comprobación
F.S. =
3.899
> 2
CUMPLE
AL ASENTAMENTO
Punto aplicación resultante :
1.603
m
ComprobaciónExcentricidad (e) :
0.197
m
e < B/6
CUMPLE
Esfuerzos máximos :
11.559
Tn/m2
CUMPLE
Esfuerzos mínimos :
5.841
Tn/m2
CUMPLE
ANALISIS A COMPRESIÓN, TENSIÓN Y A CORTE
Valores admisibles
A compresión:
94.50
kg/cm2
A tracción :
5.80
kg/cm2
A corte :
4.20
kg/cm2
Análisis en el muro
Fuerza horizontal =
6.379
Tn
Fuerza vertical =...