Model CBLE Boilers
Dimensions and Ratings

125 - 800 HP

CB-7770
09-09

CBLE

Dimensions and Ratings

Table A1-1. Model CBLE Steam Boiler Ratings
BOILER HP

125

150

200

250

300

350

400

500

Rated Steam Cap. (lbs/hr
from and @ 212 °F)

4313

5175

6900

8625

10350

12075

13800

Btu Output (1000 Btu/hr)

4184

5021

6695

836910043

11716

13390

600

700

750

800

17250

20700

24150

25875

27600

16738

20085

23432

25106

26779

RATINGS SEA LEVEL TO 700 FT

APPROXIMATE FUEL CONSUMPTION AT RATED CAPACITY
Light Oil (gph)A

36.4

43.7

58.3

72.9

87.5

102.1

116.6

145.8

175.0

204.1

218.7

233.3

Natural Gas (cfh) MBtu

5103

6124

8165

1020612247

14288

16329

20412

24494

28576

30618

32659

Gas (Therm/hr)

51.0

61.2

81.7

102.1

122.5

142.8

163.3

204.2

245.0

285.8

306.2

326.6

POWER REQUIREMENTS - SEA LEVEL TO 700 FT, 60 HZ
Blower Motor hp

Refer to Tables A1-9 and A1-10

Oil Pump Motor, hp No. 2 Oil

1/2

1/2

1/2

1/2

3/4

3/4

3/4

3/4

3/4

11

1

Air Compressor Motor hp (Oil
firing Only)

3

3

3

5

5

5

7-1/2

7-1/2

7-1/2

7-1/2

7-1/2

7-1/2

NOTES:
A. Based on 140,000 Btu/gal.

Table A1-2. Model CBLE Hot Water Boiler Ratings
BOILER HP

125

150

200

250

300

350

400

500

600

700

750

800

Rated Cap. Btu Output (1000 Btu/hr)

4184

5021

POWER REQUIREMENTS- SEA LEVEL TO 700 FT, 60 HZ
6695
8369 10043 11716 13390 16738 20085 23432

25106

26779

Light Oil (gph)A

36.4

43.7

58.3

72.9

87.5

102.1

116.6

145.8

175.0

204.1

218.7

233.3

Natural Gas (cfh) MBtu

5103

6124

8165

10206

12247

14288

16329

20415

Gas (Therm/hr)

51.0

61.2

81.7

102.1

122.5

142.9

163.3

204.224494

28576

30618

32659

245.0

285.8

306.2

326.6

APPROXIMATE FUEL CONSUMPTON AT RATED CAPACITY

POWER REQUIREMENTS - SEA LEVEL TO 700 FT, 60 HZ
Blower Motor hp
Oil Pump Motor, hp No. 2 Oil
Air Compressor Motor hp (Oil firing Only)

Refer to Tables A1-9 and A1-10
1/2

1/2

1/2

1/2

3/4

3/4

3/4

3/4

3/4

1

1

1

3

3

3

5

55

7-1/2

7-1/2

7-1/2

7-1/2

7-1/2

7-1/2

NOTES:
A. Based on 140,000 Btu/gal.

2
09-09

Dimensions and Ratings

CBLE

A
B
D

C

O

E
BB

CC

P

DD EE

R

S

Q

KK

G

FF

F

K

AA
GG

JJ
L

M

Y

T

Y

JJ

FF
GG
GG
V

HH
H

U

HH
W
X

N
I

J

Figure A1-1. CBLE Steam - 125-200 HP

Table A1-3. ModelCBLE Steam Boiler Dimensions,
60” (15 - 150 psig Design Pressure) - Sheet 1 of 2
(measurements shown in inches)
Description

125

DIM

Boiler HP
150

200

LENGTHS
Length Overall
Shell
Front Head Extension
Front Ring Flange to Nozzle - 15#
Front Ring Flange to Nozzle - 150#
Rear Head Extension
Front Ring Flange to Panel
Ring Flange to Base
Base Frame
Rear Flange Ring to BaseA
B
C
D
D
E
G
H
I
J

173
125
28
88
84
19.5
17
0.5
112
12.5

196.5
149
28
90
84
19.5
17
0.5
136
12.5

228.5
180
29
96
96
19.5
17
0.5
167
12.5

HEIGHTS
Ht Overall
Base to Vent Outlet
Base to Boiler Centerline
Base to Gas Train

K
L
M
N

86
85
46
6

86
85
46
8.5

86
85
46
8.5

3
09-09

CBLE

Dimensions and Ratings
TableA1-3. Model CBLE Steam Boiler Dimensions,
60” (15 - 150 psig Design Pressure) - Sheet 2 of 2
Description

DIM
125

Boiler HP
150

200

HEIGHTS (continued)
Base to Panel Top
Base to Panel Bottom
Height of Base
Base to Steam Nozzle

T
U
V
Y

75
15
12
82.38

75
15
12
82.38

77
17
12
82.38

WIDTHS
Width Overall
Center to ALWCO
Center to Outside Control Panel...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • Ingeniero Industrial
  • Ingeniero Industrial
  • Ingeniero Industrial
  • Ingeniero Industrial
  • Ingeniero Industrial
  • Ingeniero Industrial
  • Ingeniero Industrial
  • Ingeniero Industrial

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS