59 1/2" MIN 151 MIN

Opening for FAST module to sit on tank

350 Gallon MIN [1300 L MIN] Treatment Zone Settling Zone See Note 6 C L
25" 63.5 31 1/4" MIN 79.4 MIN

NOTES 1. Blower piping to FAST® may not exceed 100 FT [30.5m] total length and use 4 elbows maximum. For distances greater than 100 FT [30.5m] - consult factory. Blower must be located above flood/standing water levels on aconcrete base 24" X 18" X1" [61X45.7X2.6cm] minimum. 2. Vent to be located above finish grade or higher to avoid infiltration. Cap with vent grate w/at least 7.1 sq in. [45.8 sq. cm] open surface area. Secure with stainless steel screws (see sheet 4 of 4 MicroFAST® 0.50 Details.) or Run vent to desired location and cover opening with vent grate w/at least 7.1 sq in. [45.8 sq. cm] of open surface area.Secure with stainless steel screws. Vent piping must not allow excess moisture build up or back pressure. 3. All appurtenances to FAST® (e.g. tank pump outs, etc.) must conform to all country, state, province, and local plumbing and electrical codes. The blower control system is provided by Bio-Microbics, Inc. 4. Tank volume must be increased by 20% if minimum of 10 inches [25.5cm] is usedbetween the unit and the base of tank. Consult factory for approval. 5. The primary compartment may be a separate tank. 6. Either the influent pipe tee shall be fitted with a pipe cap or the baffle separating the two zones shall be extended to the top of the tank. If choosing to use the pipe cap, then the baffle shall be at least 3"[8] higher than the water level as shown on the drawing. 7. Allinspection, viewing and pump out ports must be secured to prevent accidental or unauthorized access 8. Tank, anchors, piping, conduit, blower housing pad and vents are provided by others. 9. All piping and ancillary equipment installed after FAST® must not impede or restrict free flow of effluent. 10. No more than 4 FT [1.2 m] of fill may be placed over unit lid. Unit may stand inside tank (see sheet 2 of4 MicroFAST® 0.50 with feet). Refer to installation manual for more details.
DO NOT SCALE UNLESS NOTED DIMENSIONS ARE IN INCHES [CENTIMETERS] TOLERANCES ± 0.02 IN/IN [± 0.05 CM/CM]
WEIGHT
NAME

54" 137.2

450 Gallon MIN [1700 L MIN]
Electrical conduit from blower control system to blower/blower housing. See note 1, 3, & 8. 23 7/8" 60.8 20" 50.7 Inspection/ Pump out Ports see note 3, 7, &8 6" [15] Inspection Port/Vent see note 3, 7, & 8

2 1/2" 6.4 border for sealing and securing the lid and liner to tank

3" [8] MIN vent pipe see Note 2 &8

Joints must be water tight
4' MAX 1.2m MAX

2" MIN [5cm MIN] Blower Piping

6 1/2" 16.5

3" MIN 8 MIN

15 1/8"±1/8" 38.4±0.3

Settling Zone

Influent waste See Note 6
6" 4" 15 10

4" MIN 10 MIN

4" [10] FAST treatedeffluent see note 9
41 1/4" MIN 104.6 MIN

See note 5

Treatment Zone
10" MIN 25.5 MIN See Note 4

MicroFAST 0.50 FAST Unit
SIZE DRAWING NUMBER

lb
DATE CTC 12/18/2006

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BIO-MICROBICS INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BIO-MICROBICS INC. IS PROHIBITED. DESIGN AND INVENTION RIGHTSARE RESERVED. IN THE INTEREST OF TECHNOLOGICAL ADVANCEMENT, ALL PRODUCTS ARE SUBJECT TO DESIGN AND OR MATERIAL CHANGE WITHOUT NOTICE.

BIO-MICROBICS © 2008 DRAWN

A

MicroFAST® 0.50 with lid
REV. INI-02-A

CHECKED PF

SHEET 1 OF 4

7/22/2008 REVISED Tuesday, July 22, 2008

Air Line 450 Gallon MIN [1700 L MIN] 350 Gallon MIN [1300 L MIN]

31 3/8"±1/4" 79.7±0.6

Treatment Zone15"±1/4" 38.1±0.6

NOTES 1. Blower piping to FAST® may not exceed 100 FT [30.5m] total length and use a maximum of 4 elbows in the piping system (@ 100FT [30m]). For distances greater than 100 FT [30m] consult factory. Blower must be located above flood levels on a concrete base 24" X 18" X1" [61 X 45.7 X 2.6cm] min C L
30" MIN 76.2 MIN 31 1/4" MIN 79.4 MIN

See Note 6

Settling Zone...
Leer documento completo

Regístrate para leer el documento completo.

Estos documentos también te pueden resultar útiles

  • planta de tratamiento
  • Planta De Tratamiento
  • tratamiento en las plantas
  • planta de tratamiento
  • Planta de tratamiento
  • planta de tratamiento
  • plantas de tratamientos
  • plantas de tratamiento

Conviértase en miembro formal de Buenas Tareas

INSCRÍBETE - ES GRATIS