Tsu en electronica
16-02-2010
8:07
Pagina 1
Submittal Data
GA Line ACF Series
Commercial and Specialty Chillers
Small Tonnage Gas Fired Absorption Chillers With Modular Capability
Cooling
The High Efficiency Chillers
ammonia for the production
The evacuation of combustion
ACF60-00 series are water
of chilled water.
gases occurs by mixing them
chillers,equipped with an
The chilling system is fed by
with condenser air using the
air-cooled condenser and
thermal energy provided by a
axial fan of the appliance; no
designed for outdoor
gas burner, therefore the
flue is needed.
installation. The absorption
required electric energy is
The combustion fuel is
cooling cycle is based upon
limited to driving the fanand
natural gas or LPG.
a solution of water and
pump motors.
Versions
Control and safety devices
generator; helps prevent
valve, the air pressure
The ACF series is available in
The ACF series units are
overheating of the generator;
switch, the air blower and
four versions:
equipped with the following
ST - Designed for comfort
components and safetyswitch; located inside the
• dual gas valve;
conditioning in standard
devices:
rear portion of the
• chilled water flow sensor;
applications with design
• steel sealed circuit, painted
combustion chamber; helps
located on the return chilled
ambient temperatures of
with external epoxy paint;
prevent overheating of the
water line; it monitors the
generator;water flow and helps
104 °F or lower.
• steel tube air exchanger with
HT - Designed for
single-row coil and
applications in which the
aluminum fins;
design ambient temperatures
• titanium stainless steel tube
• flue gas temperature limit
• sealed circuit safety relief
valve;
• premixed multigas burner
the flame sensor;
prevent freezing of the
evaporator;
•safety by-pass valve;
are expected to exceed
bundle water heat
with ignition and flame
located inside the sealed
104 °F.
exchanger, with external
sensing device managed by
system; prevents over
TK - Designed for Industrial
insulation;
an electronic control box;
pressurizing the sealed
and commercial applications
requiring heavy use on a
year round basis.
•variable speed condenser
• differential air pressure
fan, microprocessor
switch; located inside the
controlled;
system;
• antifreeze function for
electric box; it helps manage
hydronic system; together
• S60 Electronic Control
the combustion system by
with the flow switch, this
requiring chilled water
Board with integrated
monitoring the air flowingelectronic function,
temperatures down to 14 °F.
microprocessor, LCD display
into the air-gas mixing
programmed into the
ACF units are natural gas or
and encoder located inside
chamber and stopping the
microprocessor, helps
LPG fired and require 208 -
the electric box; it is
burner if the air flow is too
prevent freezing of the
230V 60Hz SINGLE PHASEprogrammable and it
low;
electrical power.
controls and monitors the
LB - Designed for applications
operation of the chiller;
• ignition control box; located
evaporator;
• temperature probes; located
inside the electric box; it
both on the sealed system
manages the combustion
and on the water lines; they
temperature limit; located
system controlling the
monitorfunctional
on the external wall of the
burner ignition, the gas
parameters of the unit.
• sealed circuit high
1
ROBUR_ACF_submittal.qxt
16-02-2010
8:07
Pagina 2
Submittal Data
ROBUR GA Line ACF Series
PERFORMANCE RATINGS (1)
Cooling capacity (2)
Gas input
Ambient operating temperature
Chilled water temperature
Chilled water flow
BTU/h
BTU/h
°F...
Regístrate para leer el documento completo.