Sensores
Dimensions
NJ1,5-18GM-N-D-V1
M18 x 1 ø 15 f9 0.1 A
15 4 35 24 M12 x 1 14
NAMUR, NC 1.5 mm embeddable DC 0 ... 1.22 mm 0.4 0.3 0.85 8.2 V (Ri approx. 1 kΩ) 0 ... 400 Hz typ. % ≥ 3 mA ≤ 1 mA 350 bar (5076.4 psi) -25 ... 85 °C (-13 ... 185 °F) Device connector M12 x 1 , 4-pin Stainless steel 1.4305 / AISI 303 Ceramic IP67 see instruction manuals 2G; 1D EN 60947-5-6:2000IEC 60947-5-6:1999 EN 60947-5-2:2007 IEC 60947-5-2:2007 cULus Listed, General Purpose cCSAus Listed, General Purpose
installation direction
0102
Model Number
NJ1,5-18GM-N-D-V1
Features
• • • 1.5 mm embeddable Compression proof up to 350 bar, dynamic on active surface Usable up to SIL2 acc. to IEC 61508
Technical Data
General specifications Switching element function Rated operatingdistance sn Installation Output polarity Assured operating distance sa Reduction factor rAl Reduction factor rCu Reduction factor r304 Nominal ratings Nominal voltage Uo Switching frequency f Hysteresis H Current consumption Measuring plate not detected Measuring plate detected Limit data Operating pressure Ambient conditions Ambient temperature Mechanical specifications Connection type Housingmaterial Sensing face Protection degree General information Use in the hazardous area Category Compliance with standards and directives Standard conformity NAMUR Standards
Connection
1
L+
2
L-
Pinout
1 2 3 4
Approvals and certificates UL approval CSA approval
Date of issue: 2012-02-17 106344_eng.xml
Wire colors in accordance with EN 60947-5-6 1 2 BN BU (brown) (blue)Thread undercut D DIN 76 L ø15 H8 (d1) M18 x 1 6H (d2)
Accessories
V1-G
4-pin, M12 female field-attachable connector
15° - 30°
0.6 x O-cord thickness (= 1.5) L: recommended installation depth: L ≥ 0.8 x d2
Release date: 2012-02-16 14:28
V1-W
4-pin, M12 female field-attachable connector
V1-W-N-2M-PUR
Cable socket, M12, 2-pin, NAMUR, PUR cable
V1-G-N-2M-PUR
Cable socket, M12,2-pin, NAMUR, PUR cable
Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com
Germany: +49 621 776-4411 fa-info@pepperl-fuchs.com
Copyright Pepperl+Fuchs Singapore: +65 6779 9091 fa-info@sg.pepperl-fuchs.com
45
1
Inductive sensor
ATEX 2G Instruction Device category 2G Directive conformity Standardconformity
NJ1,5-18GM-N-D-V1
Manual electrical apparatus for hazardous areas for use in hazardous areas with gas, vapour and mist 94/9/EG EN 60079-0:2006, EN 60079-11:2007 Ignition protection "Intrinsic safety" Use is restricted to the following stated conditions 0102 ¬ II 2G Ex ia IIC T6 PTB 00 ATEX 2048 X NJ1,5-18GM-N-D.. ≤ 50 nF ; a cable length of 10 m is considered. ≤ 60 µH ; a cablelength of 10 m is considered. The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The EC-Type Examination Certificate has to be observed. The special conditions must be adhered to! Directive 94/9/EG and hence also EC-Type Examination Certificates apply in general only to the use of electrical apparatus under atmospheric conditions. Theuse in ambient temperatures of > 60 °C was tested with regard to hot surfaces by the mentioned certification authority. If the equipment is not used under atmospheric conditions, a reduction of the permissible minimum ignition energies may have to be taken into consideration. The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Laws and/orregulations and standards governing the use or intended usage goal must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.
CE symbol Ex-identification EC-Type Examination Certificate Appropriate type Effective internal capacitance Ci Effective internal inductance Li General
Highest permissible...