Hoy bien hecho

Páginas: 17 (4012 palabras) Publicado: 17 de septiembre de 2010
File E65048

Project 89ME4819/E125359

Issued: 1989-10-19
Revised: 2003-12-09

REPORT

on

EMERGENCY LIGHTING AND POWER EQUIPMENT

Cooper Industries Inc.
Cooper Lighting, Div. of
Peachtree, GA

Copyright 1989 Underwriters Laboratories Inc.

Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety.File E65048 Vol. 1 Sec. 52 Page 1 Issued: 1989-10-19
and Report Revised: 2003-12-09

DESCRIPTION

PRODUCT COVERED:

Unit Equipment - Models 6 followed by A or X; followed by C; followed by NY; followed by 1, 3, 4, 5 or 7. Model 12 followed by A or X; followed by C; followed by NY; followed by 2, 3, 4 or 5. Models 6 followed by A or X; followed by C; followed by 10, 27, 36, 54,or 100. Models 12 followed by A or X; followed by C; followed by 30, 36, 54, or 100. Model 12 followed by H or X; followed by C; followed by 200, 300, or 400. Model 12 followed by H or X followed by C; followed by NY; followed by 7, 8, or 9. Model 12 followed by B; followed by C; followed by NY; followed by 2, 3, or 4. Model 12 followed by B; followed by C; followed by 30, 36, or 54.Models 6BC10, 6BC27 and 6BCNY1. Models R, prefixed by 6 or 12; followed by OB; followed by 10 or 24.

GENERAL CHARACTERISTICS AND USE:

(Unit Equipment)

The devices covered by this report are emergency lighting units intended to provide a source of illumination in the event of an ac power supply failure. These units are for permanent (conduit knockouts provided) installation or cord connection(cord provided). Each unit is provided with a battery and battery charging circuit. Provision for remote lampheads.

File E65048 Vol. 1 Sec. 52 Page 2 Issued: 1989-10-19
and Report Revised: 2003-12-09

RATINGS

Batteries                

NY
Input     
Output   
Discharge
Atlite

Rating

Model 
Model 
V   



Time (h)Part No.
Mfr's
Type   
(V, AH)
Amount
PWA  
 XFMR  

6AC10
-
120/277
42
6
10
1-1/2
24-1001
EP
CFM6V4.6
6, 4.6
1
55-1002
12-1101

24-1002
PANA
LCR6V4P
6, 4
1
55-1001

CSB
GP4-6
6, 4
1

6AC27
6ACNY1
120/277
42
6
27
1-1/2
24-1004
EP
CFM6V9.5
6, 9.5
1
55-1002
12-1101

24-1003
EP
CFM6V10
6, 10
1
55-1001

PANA
LCR6V10R
6, 10
1

PS
PS6100F6, 10
1

CSB
CP10-6
6, 10
1

6AC36
6ACNY3
120/277
42
6
36
1-1/2
24-1004
EP
CFM6V9.5
6, 9.5
2P
55-1002
12-1101

24-1003
PANA
LCR6V10R
6, 10
2P

6AC54
6ACNY4
120/277
42
6
54
1-1/2
24-1004
EP
CFM6V9.5
6, 10
2P
55-1002
12-1104

24-1003
PANA
LCR6V10R
6, 10
2P
55-1003
12-1104
12AC100
6ACNY5
120/277
10
6
100
1-1/2
24-1006
EP
CFM6V33
6, 33
1PWR
PRC636
6, 36
1

PM
PM6360
6, 36
1
55-7001
12-1103
6AC200
6ACNY7
120/277
14
6
200
1-1/2
24-1006
EP
CFM6V33
6, 33
2P
55-1003
12-1104

PM
PM6360
6, 36
1
55-7001
12-1103
12AC30
12ACNY2
120/277
42
12
27
1-1/2
24-1007
EP
CFM6V6
6, 6
2S
55-1002
12-1201

24-1003
PANA
LCR6V10R
6,10
2S
55-1002
12-1201

BB
BP10-6
6,10
2S
55-6001M
12-1103RBB -
BB Battery

PS -
Power Sonic
CSB -
China Storage Battery

PWA -
Printed Wiring Assembly
EP -
Eagle Picher

PWR -
Power Battery
P -
Parallel

S -
Series
PANA -
Panasonic

SP -
Series Parallel
PM -
Power Mate

XFMR -
Transformer

File E65048 Vol. 1 Sec. 52 Page 3 Issued: 1989-10-19
and Report Revised: 2003-12-09

RATINGSBatteries                  

NY
Input     
Output   
Discharge
Atlite

Rating

Model 
Model 
V   



Time (h) 
Part No.
Mfr's
Type   
(V, AH)
Amount
PWA  
XFMR  

12AC36
12ACNY3
120/277

12
36
1-1/2
24-1004
EP
CFM6V9.5
6, 9.5
2S
55-1002
12-1201

24-1011
PANA
LCR6V6.5
6, 6.5
2S
55-6004M
12-1201R
12AC54...