Mecanico
A S S E M B L Y
I N S T R U C T I O N
Controller Model: Maple OIT Model:
Entertron Industries Controllers Blue Series
Communication Type: RS-232 withLeads at Controller
Use the wiring diagram and illustration to assemble a communication cable for use with an Entertron Industries SK1600-R-SA, Smart-Pak, Smart-Pak Plus, or Elite2000 controller.
4-40 x 1/2 Retainer Screw, 2 places 18 AWG Green wire DE9 S Connector and DE9 Backshell 4 Pair 26 AWG Shielded cable, Category 5
#6 Crimp Lug
To ChassisGround
3/8" Heatshrink Tubing
OIT END NOTES: Twist together 18 AWG green wire and shield wire. Solder 1 wires and insulate with heatshrink to avoid shorting.
2
CONTROLLEREND
Solder shield wire to the DE9S connector metal shell. Install heatshrink tubing over the shield wire to avoid shorting.
1
Green
To Chassis Ground
Controller
TXDRXD Ground
OIT
2
9S Shield Brown Green Blue
RXD 2 TX D 3 Return 5
1025-0053, Rev 00
C A B L E
A S S E M B L Y
I N S T R U C T I O N
Controller Model:Maple OIT Model:
Entertron Industries Controllers BLU300 Series
Communication Type: RS-485 with Leads at Controller
Use the wiring diagram and illustration to assemble acommunication cable for use with Entertron Industries SK1600-R-SA, Smart-Pak, Smart-Pak Plus, or Elite 2000 controller.
#6 Crimp Lug 18 AWG Green wire
To Chassis Ground
4 Pair26 AWG Shielded cable, Category 5
3/8" Heatshrink Tubing
OIT END NOTES: Twist together 18 AWG green wire and shield wire. Solder 1 wires and insulate with heatshrink toavoid shorting.
1
CONTROLLER END
OIT
Shield
0V
Green
To Chassis Ground Controller
Signal Ground
Blue White w/Brn Stripes Brown
+
+
1025-0054, Rev 01